Biosan LMC-4200R User Instructions

Biosan LMC-4200R User Instructions

Laboratory centrifuges

Advertisement

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the LMC-4200R and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Biosan LMC-4200R

  • Page 2: Table Of Contents

    EU Declaration of conformity .................. 15 About this edition of user instructions The current edition of the user instructions applies to the following models and ver- sions of laboratory centrifuges:  LMC-3000 ................versions V.6AD, V.6AE  LMC-4200R ..................version V.4AD...
  • Page 3: Safety Precautions

    Safety precautions The following symbols mean: Caution! Make sure you have fully read and understood the present Manual before using the equipment. Please pay special attention to sections marked by this symbol. GENERAL SAFETY  The protection provided can be ineffective if the operation of the appliance does not comply with the manufacturer's requirements.
  • Page 4 DURING OPERATION  Do not centrifuge flammable or chemically active substances. If such liquids are spilled on the rotor or rotor chamber, the centrifuge must be cleaned with a moist cloth and a mild soap solution.  Do not use rotors with visible signs of corrosion, wear or mechanical damage. ...
  • Page 5: General Information

    After non-stop centrifugation for 1.5 hours, temperature in the working chamber of the LMC-3000 model can rise, but not by more than 15°C higher than ambient. In case of centrifugation of thermally sensitive samples, we recommend using LMC-4200R model, la- boratory centrifuge with cooling function.
  • Page 6: Getting Started

    The warranty does not cover in-transit damage. Warranty covers only the units transported in the original package. Caution! Due to the high weight of the LMC-4200R unit, its unpacking and in- stalling must be carried out by two persons. 4.2.
  • Page 7 According to EN 61010-2-20, people and hazardous materials must not be within a 300 mm area around the device during the centrifuge operation. (LMC-4200R) Be sure to cork the drain hose (fig. 2/1) on the left side of the unit with a stopper to prevent the rising of chamber temperature.
  • Page 8: Operation

    Check the power cable for any signs of damage. Connect the power cable to a properly grounded mains socket. Set the power switch on the side to position I (on). Caution! In model LMC-4200R, cooling system requires some time for start- up. After powering up, wait for about 4 minutes before centrifugation. 5.2.
  • Page 9 Values convert after changing units. RCF depends on selected rotor or adapters, as shown in Table 1. 5.4.5. Chamber temperature (fig. 5/7, only for LMC-4200R). Select the chamber tempera- ture, step 1 °C. Cooling starts independently from centrifugation.
  • Page 10 5.12.3. LMC-4200R. Insert the emergency opening tool into the slot on the right side of the unit, above the power switch (fig. 3/1). Push until a click is heard and open the un-...
  • Page 11: Specifications

    80% for temperatures up to 31°C decreasing linearly to 50% relative humidity at 40°C. Biosan is committed to a continuous programme of improvement and reserves the right to alter design and specifications of the equipment without additional notice.
  • Page 12: Ordering Information

    V.4AD 230 V, 50 Hz BS-010212-AAA 7.2. To inquire about or order the optional accessories or the replacement parts, contact Biosan or your local Biosan representative. 7.2.1. Optional accessories. Rotors and rotor holder. Maximum speed / RCF Catalogue num- Model...
  • Page 13: Care And Maintenance

    For the ease of cleaning, chamber is equipped with a drain hole with tube (fig. 2/1). 8.3.4. (For LMC-4200R) Clean the condenser of the unit at least once per year. Disconnect from electric circuit. Unscrew 4 screws and remove the grate on the rear panel of the unit, then vacuum the condenser.
  • Page 14: Warranty

    Extended warranty.  For LMC-4200R, the Premium class model, one year of extended warranty is availa- ble free of charge after registration, during 6 months from the date of sale. Online registration form can be found in section Warranty registration on our website at the link below.
  • Page 15: 10. Eu Declaration Of Conformity

    10. EU Declaration of conformity Unit type Mini-centrifuge, laboratory centrifuges Models Microspin 12, LMC-3000, LMC-4200R Serial number 14 digits styled XXXXXXYYMMZZZZ, where XXXXXX is model code, YY and MM – year and month of production, ZZZZ – unit number. Manufacturer SIA BIOSAN Latvia, LV-1067, Riga, Ratsupites str.
  • Page 16 Biosan SIA Ratsupites 7, build.2, Riga, LV-1067, Latvia Phone: +371 67426137 Fax: +371 67428101 http://www.biosan.lv Edition 4.-6.02 – December of 2018...

This manual is also suitable for:

Lmc-3000