1 - INTRODUCTION: SENSOR REPRESENTATION IN THE HOME SCREEN
Main screen
S1
Boat access control
S2
Bilge 1 control
S3
Engine access control
S4
Engine battery control
S5
Generator battery control
S6
Bilge 2 control
S7
Hatch 1 control
S8
Hatch 2 control
ICON COLOUR KEY
ENABLED DISABLED ALARM
S6
S2
C1
S7
S8
S4
S1
S5
S3
USER MANUAL MI004913-E
N.B.:
The warning about cabin access or en-
gine compartment opening is always in
real time.
Temperature detection takes place every
15 minutes. In case of variation in sta-
tus, the alarm is given in real time.
Battery voltage detection takes place
every 15 minutes. In case of variation in
status, the alarm is given in real time.
The bilge water level sensor signals the
alarm in real time. If there is no water in
the bilge, the alarm is deactivated after
15 minutes.
If a sensor does not communicate with
the control unit for over 100 minutes, all
the alarms of the involved sensor will be
activated.
C1
Monitoring the status of the service
battery takes place via the MyBoat
control unit and its power supply
connector. With this it is possible to
detect the status and voltage of the
service battery it is connected to.
07