Hide thumbs Also See for MyBoat:

Advertisement

Quick Links

User Manual
1
USER MANUAL MI004913-E

Advertisement

Table of Contents
loading

Summary of Contents for Seneca MyBoat

  • Page 1 User Manual USER MANUAL MI004913-E...
  • Page 2 ACTIVATION CODE USER MANUAL MI004913-E...
  • Page 3: Table Of Contents

    2 - INSTALLATION -Installation of the MyBoat control unit -Replacing the sensor battery -Sensor installation p.10 3 - ACTIVATION -Cloud account registration and MyBoat service activation p.16 -Product activation p.17 4 - MYBOAT MOBILE APP -HOME screen p.20 -STATUS screen p.21...
  • Page 4: Introduction: Content Of The Pack

    1 - INTRODUCTION: CONTENT OF THE PACK 1 - MyBoat control unit 2 - Sensors (the image refers to a kit with 8 sensors) 3 - User Manual 4 - SIM card (optional, see leaflet) 5 - Power cable with cigarette lighter plug...
  • Page 5: Logical Diagram Of The Myboat System

    1 - INTRODUCTION: LOGICAL DIAGRAM OF THE MYBOAT SYSTEM From 2 to 8 sensors (*) Analogue inputs Digital inputs DIN1 DIN2 AUX 1 AUX 2 AIN 2 DIN3 DIN4 Relay digital outputs Power supply (*) According to the KIT purchased, check the information on the side of the pack...
  • Page 6: Product Description

    SENECA makes available various types of kits consisting of various sensors to monitor: the boat access points, the state of the engine compartment, the state of the service, engine and general batteries, the current position of the boat, the water level in the bilges and the temperature both in the cabin and in the bilge.
  • Page 7: Myboat Control Unit

    1 - INTRODUCTION: MYBOAT CONTROL UNIT MyBoat control unit The MyBoat control unit is a product derived from SENECA MyAlarm3. Remote alarm, telemetry and datalogging industrial unit. Technical characteristics: • Display LCD 128 x 32 Dots • Rechargeable Li-Io buffer battery, up to 8 hours’ autonomy • Replaceable GSM/GPRS/GPS antenna on SMA connector •...
  • Page 8: Monitoring Sensors

    868 Mhz radio frequency. They are fitted with 3V CR2 batteries guaranteeing their operation for about 1 year (*). With the MyBoat app, you can monitor the state of the batteries of the individual sensors, to foresee their Front view of a magnetic sensor Bilge water level detector replacement.
  • Page 9: Sensor Representation In The Home Screen

    Hatch 2 control ICON COLOUR KEY Monitoring the status of the service ENABLED DISABLED ALARM battery takes place via the MyBoat control unit and its power supply connector. With this it is possible to detect the status and voltage of the service battery it is connected to.
  • Page 10: Installation: Installation Of The Myboat Control Unit

    2 - INSTALLATION: INSTALLATION OF THE MYBOAT CONTROL UNIT N.B.: To switch it off, keep the PWR key For optimum reception of the GPS pressed for a few seconds. signal given by satellites, it is better The device is fitted with a SCR key, to place the MyBoat horizontally on in the RH top corner. Pressing this a surface in an area not covered key displays the parameters.
  • Page 11: Replacing The Sensor Battery

    2 - INSTALLATION: REPLACING THE SENSOR BATTERY screw 1 screw 2 All sensors are factory-set and sup- plied with a battery. To replace the batteries in the sensors, follow the following instruc- tions: • With a cross head screwdriv- er, remove the two fastening screws from the dome as shown in Figure 1; • Open the dome paying attention to the orientation as in Figure 2; Figure 1 Figure 3 •...
  • Page 12: Sensor Installation

    2 - INSTALLATION: SENSOR INSTALLATION S1 Boat access control 1. Remove the protection tab to power the sensor; 2. Identify the installation point of both the sensor (e.g. door frame, lintel) and the magnet (assess whether to use a type 1 or type 2 magnet, according to require- ments) and clean the 2 areas identified;...
  • Page 13 2 - INSTALLATION: SENSOR INSTALLATION S2 and S6 Bilge 1 and 2 control 1. Remove the protection tab to power the sensor; 2. Identify the installation points of the sensor and level contact, pulling the cable supplied (as in Figure 1) and clean the two areas identified; 3. Remove the velcro protection film from both the sensor and the contact and apply in the two areas identified, pressing lightly...
  • Page 14 2 - INSTALLATION: SENSOR INSTALLATION S3 Engine access control 1. Remove the protection tab to power the sensor; 2. Identify the installation point of both the sensor (e.g. door frame, lintel) and the magnet (assess whether to use a type 1 or type Engine compartment 2 magnet, according to require- closed ments) and clean the 2 areas identified;...
  • Page 15 2 - INSTALLATION: SENSOR INSTALLATION S4 and S5 Engine and service battery control 1. Remove the protection tab to power the sensor; 2. Identify the installation point of the sensor according to the length of the cable to connect to S4/S5 sensor the battery and clean the area identified;...
  • Page 16 2 - INSTALLATION: SENSOR INSTALLATION S7 and S8 Hatch 1 and 2 control 1. Remove the protection tab to power the sensor; 2. Identify the installation point of both the sensor (e.g. door frame, lintel) and the magnet (assess whether to use a type 1 or type 2 magnet, according to require- ments) and clean the 2 areas Closed hatch identified;...
  • Page 17 USER MANUAL MI004913-E...
  • Page 18: Activation: Cloud Account Registration And Myboat Service Activation

    3 - ACTIVATION: CLOUD ACCOUNT REGISTRATION AND MYBOAT SERVICE ACTIVATION To use the MyBoat monitoring the back cover of this manual • Register and log in for the first system you need to create a SENE- (**) and select the “ADD” but- time; • Once you have logged in the CA Cloud account and activate the ton again;...
  • Page 19 3 - ACTIVATION: CLOUD ACCOUNT REGISTRATION AND MYBOAT SERVICE ACTIVATION settings Fleet management • Select “Cloud Services” • EDITOR: displays information, Through the Cloud platform console • Select the “MANAGEMENT” sends commands button for the Service you wish you can manage multiple MyBoat • USER: displays information to reset.
  • Page 20 3-ACTIVATION: CONNECTION INSTRUCTIONS OF THE DEVICE TO CLOUD SENECA SWITCH ON CONNECTED CONNECTED GSM SEARCH SHUTDOWN POWER UNIT TO GSM TO CLOUD STATUS REPORTS MEANING DURATION GSM LED Yellow flashing The control unit is sear- GSM SEARCH Fast and no GSM signal...
  • Page 21 Move the control unit, wait at least 1 minute and check that the number of GSM signal notches on the display becomes greater than GSM signal failure 1. Contact Seneca technical support for the purchase of an external The control unit is in antenna the “GSM SEARCH”...
  • Page 22: Myboat Mobile App -Home Screen

    4 - MYBOAT MOBILE APP: HOME SCREEN Siren activation Access another boat Service battery Localization Weather report of the Engine battery boat position Generator battery Settings Dock voltage Bilge flooding Bilge flooding Hatch 1 Hatch 2 Cabin temperature NOTIFICATION AREA Cabin door...
  • Page 23: Status Screen

    4 - MYBOAT MOBILE APP: STATUS SCREEN Alarm status Perimeter alarm Flooding alarm Temperature alarm Battery voltage alarm Alarm activation Alarm deactivation Shifts AUX1 for 1 min. Shifts AUX2 Area for the display of op- tional advanced functions ADVANCED FUNCTIONS...
  • Page 24: History Screen

    Error code HISTORY FUNCTION The history function allows display- ing and filing the alarm messages sent by the MyBoat system to have a constant record of the events of the individual actions and/or commands of all the users. USER MANUAL MI004913-E...
  • Page 25: Settings Menu

    4 - MYBOAT MOBILE APP: SETTINGS MENU Close the application Notification configuration General parameters Commands for SMS notification To check the settings, activate them in the general parameters Phonebook for SMS setup section. To send and receive SMS to the Cloud account and MyBoat MyBoat control unit, save your telephone number in the “SMS...
  • Page 26 4 - MYBOAT MOBILE APP: GENERAL SETTINGS Name of the boat Alarm AUX1 setting Alarm AUX2 setting Displays the fuel level (Op- tional advanced configura- tion on page 29) Displays digital inputs (Optional advanced configu- ration on page 29) Icons size configura Saves modifications Cancels modifications GENERAL SETTINGS...
  • Page 27 4 - MYBOAT MOBILE APP: SYSTEM SETTINGS Close the application Name of the boat Type of KIT installed Terminal identification App version Connection status App last update Reception signal quality Power status USER MANUAL MI004913-E...
  • Page 28 4 - MYBOAT MOBILE APP: ACCOUNT SETTINGS Cloud connection status APP reconnection No. Cloud app exchanged packs Radio sensor setting SENSOR SETTINGS It will be possible to customise the settings of the individual sensors ac- cording to the kit purchased. USER MANUAL MI004913-E...
  • Page 29 4 - MYBOAT MOBILE APP: ACCOUNT SETTINGS Close the application Holder ID Smartphone ID App ID Username used Permits Cloud service management Exit the account USER MANUAL MI004913-E...
  • Page 30 4 - MYBOAT MOBILE APP: LOCALIZATION SCREEN Localization screen Saves position Add label Share position Download position SHARE POSITION The “share position” function allows sending the position of the boat you are logged in with, to be reached and identified easily. USER MANUAL MI004913-E...
  • Page 31 4 - MYBOAT MOBILE APP: FLEET MANAGEMENT SCREEN Close the application Boat identification Add boat Cancel operation FLEET FUNCTIONS The fleet function allows switching easily between boats of the same cloud account. With a simple touch you can go from one boat to the oth- er without having to access the app again.
  • Page 32 CHANGED” message; the new sensor); 8. At this point the procedure is 4. On the MyBoat control unit dis- complete. The configuration play, select the radio menu with menu displayed will close auto- the SCR key (top RH corner, matically; further info on page 8)
  • Page 33: Advanced Settings

    5 - ADVANCED SETTINGS: ADVANCED CONFIGURATION OF THE MYBOAT CONTROL UNIT TERMINAL BLOCK CONTACT KEY IMPORTANT: The MyBoat control unit is set for advanced functions with signal With relay contacts, the “mo- AUX 1 inputs/outputs available on the ter- (timed) bile” wiring of the cables on the minal board in the lower part of the terminals is not allowed. Common to the two relays device, under the black dome.
  • Page 34 CONTACTS AND INFORMATION Addresses Via Austria 26 - 35127 Padova (I) Tel. +39 049 8705 359 (408) Fax +39 049 8706287 Website: www.seneca.it Support: www.seneca.it/en/supporto-e-assistenza/ Email: General information: info@seneca.it Sales department: sales@seneca.it Technical support: support@seneca.it The information in this document can be modified or integrated without notice for technical or commercial reasons. The figures and diagrams are indicative and not binding.

Table of Contents