2 - INSTALLATION: SENSOR INSTALLATION
S3 Engine access control
alarm disabled
alarm enabled
12
Engine compartment
closed
Engine compartment
open
Sensor S2
Type 1 magnet
Type 2 magnet
Sensor S2
Installation detail
USER MANUAL MI004913-E
1. Remove the protection tab to
power the sensor;
2. Identify the installation point of
both the sensor (e.g. door frame,
lintel) and the magnet (assess
whether to use a type 1 or type
2 magnet, according to require-
ments) and clean the 2 areas
identified;
3. Apply the round velcro patch onto
the magnet;
4. Check it is positioned correctly
and, to guarantee it works prop-
erly, leave a maximum distance
of 10 mm between the two ele-
ments;
5. Remove the velcro protection film
from both the sensor and the
magnet, apply in the two areas
identified, pressing lightly for a
few seconds.
N.B. If it is not possible to position the
magnet and sensor on axis, use the
type 2 magnet as shown in the figure.