Technical Data 11 And - REXROTH VT-HACD-3-2 Series Manual

Digital closed-loop control electronics
Table of Contents

Advertisement

RE 30543/12.10 VT-HACD-3-2X
Technical data
Operating voltage
1)
Current consumption at 24 VDC
Processor
Analog inputs (AI)
– Voltage inputs (differential inputs)
• Channel number
• Input voltage
• Input resistance
• Resolution
• Non-linearity
• Calibration tolerance
– Current inputs
• Channel number
• Input current
• Leakage current
• Resolution
Analog outputs
AO1 configuration as voltage output
Output voltage
Output current
Load
Resolution
Residual ripple
AO1 configuration as current output
Output current
Load
Resolution
Residual ripple
AO2 / AO3
Output voltage
Output current
Load
Resolution
Residual ripple
1)
If a 24 V encoder supply is implemented directly via the
VT-HACD-3-2X (supply voltage is looped in), the transduc-
er specification has to be observed.
U
18 to 30 VDC
B
200 mA (observe additional power for connected
sensors/actuators)
32 bit power PC
Quantity 6
max. 6 (selectable via software)
U
max +15 V to –15 V (+10 V to –10 V analyzable)
E
R
> 10 MΩ (AI1)
E
200 kΩ ±5 % /AI2 to AI6)
5 mV
±0.25 %
max. 40 mV (with factory settings)
max. 6 (selectable via software)
I
0...20 mA
E
I
0.1 to 0.4 %
V
5 µA
Quantity 3
U 0...10 V or ±10 V (configurable)
I
10 mA
max
R
1 kΩ
Lmin
1.25 mV (14 bit)
±15 mV (without noise)
I 0...20 mA or 4...20 mA (configurable)
R
500 Ω
max
1.25 µA
±15 µA (without noise)
U ±10 V
I
10 mA
max
R
1 kΩ
min
1.25 mV (14 bit)
±25 mV (without noise)
Hydraulics Bosch Rexroth AG
11/16