Design; Features - Siemens SITRANS F Operating Instructions Manual

Ultrasonic flowmeters
Hide thumbs Also See for SITRANS F:
Table of Contents

Advertisement

Description

3.4 Features

3.3

Design

The transmitter type SITRANS FUS080 is designed with fiberglass reinforced polyamide
enclosure for remote or compact installation in normal areas. The remote versions are available
with up to 30 meter distance from flowmeter to transmitter. In the FUS380 and FUE380 series
the sensor cables are already mounted at the sensor.
The transmitter is available in an IP67/NEMA 4X/6 enclosure and is designed for use in the
flowmeters series:
● SONOKIT (1-path or 2-path)
● FUS380 (2-path)
● FUE380 (2-path)
For spare part cases the transmitter is always ordered as part of a complete flowmeter system,
it can be ordered preprogrammed with the given sensor data (system serial number).
3.4
Features
The following features are available:
● Battery or mains-powered transmitter
● Battery-powered with 3.6 V Lithium dual D-cell batteries
● Suitable for sensor pipe diameters from DN 50 (2") up to DN 1200 (48")
● IP67 (NEMA 4X/6) rated polyamid transmitter enclosure
● Factory preset to the nominal dimensions of pipe type and pipe size
● Programming via SIMATIC PDM
● Local control panel with single push button, 8-digit display and IrDA optical interface for
communication with SIMATIC PDM
● Display showing accumulated volume as well as instantaneous flow rate. The displayed
units are m
● Two digital outputs for volume pulse or alarm
● 4-20 mA output (optional)
20
SITRANS FUS080 transmitter
and m
/h
3
3
SITRANS FUS080 display
SITRANS FUS380/FUE380
Operating Instructions, 05/2018, A5E00730100-AE