Submersible solids handling pump. for use with product built with usem motor. (17 pages)
Summary of Contents for Hydromatic HPGFX
Page 1
HPGHX HPGFX MODELS HPGFX/HPGHX & HPGFHX/HPGHHX (Class I, Division 1, Groups C & D): FM HAZARDOUS LOCATION SUBMERSIBLE GRINDER PUMPS INSTALLATION AND SERVICE MANUAL For use with product built with Regal Beloit or Marathon motor. ® NOTE! To the installer: Please make sure you provide this manual to the owner of the equipment or to the responsible party who maintains the system.
Reasonable sensing unit and signaling device. start have a run and a start winding, care and safe methods should be This is supplied in a Hydromatic each drawing a different current. To ® practiced. Check local codes and control panel.
Failure Connection: rotation will have to be If a Hydromatic control panel is Caution: The 230 volt 3 phase checked by pump operation used, terminal blocks are provided pump has a dual marked nameplate.
2. Discharge head too high Hazardous Location Pumps: cutter ring retainer. 3. Pump or piping plugged If a Hydromatic hazardous location 5. Unscrew hex head cap screws pump is used in a hazardous 4. Wrong rotation and remove volute case.
Page 6
Effective 04-01-09 HPGFX Parts List For use with product built with Marathon motor. ® Item Eng. Item Eng. Item Eng. Description Qty. Description Qty. Description Qty. 1 152730355 35’ Cord Assembly 14-4 18 19099A029 Cap Screw 33 000650211 Bearing – Upper 152730345 35’ Cord Assembly 12-4 19 084220031 Washer, Impeller 34 108950005 Conn. Box All 230/460V/3ø...
Page 7
For pumps built prior to 04-01-09 HPGFX Parts List For use with product built with Regal Beloit motor. Item Eng. Description Qty. 1 RTF 35’ Cord Assembly 3" Flanged (76.2) 2 005570001 Wire Connector 230/460V discharge 008530001 Wire Connector, All 3 008340081 O-Ring 4 108980001 Connector 4"...
Page 8
Effective 04-01-09 HPGHX Parts List For use with product built with Marathon motor. ® Item Eng. Item Eng. Item Eng. Description Qty. Description Qty. Description Qty. 22 049160001 Shaft Seal – Lower 084340215 Rotor with Shaft 3 hp 1 152730355 35’ Cord Assembly 14-4 23 078920012 Volute (HPGHX) 208/230/460/575V/3ø 152730345 35’ Cord Assembly 12-4 078920032 Volute Horiz. (HPGHHX) 32 107650022 Motor Housing...
Page 9
For pumps built prior to 04-01-09 HPGHX Parts List For use with product built with Regal Beloit motor. Item Eng. Description Qty. 1 RTF 35’ Cord Assembly 2 005570001 Wire Connector 230/460V 008530001 Wire Connector, All 3" Flanged (76.2) 3 008340081 O-Ring discharge 4 108980001 Connector 5 116750001 Connector All 1ø & 3ø 200 & 575V 3 116750001 Connector 3ø 230/460V...
Page 12
Pentair Hydromatic will cover only the lower seal and labor thereof for all dual seal pumps. Under no circumstance will Pentair Hydromatic be responsible for the cost of field labor, travel expenses, rented equipment, removal/reinstallation costs or freight expenses to and from the factory or an authorized Pentair Hydromatic service facility.
Need help?
Do you have a question about the HPGFX and is the answer not in the manual?