INSTALL WINDOW PANEL
Installation in a double-hung sash window
(CV-PD13PX)
1
Cut the foam seal A to the proper length
and attach it to the window stool.
2
Attach 2 window exhaust adapters to
the window panel inside opening.
3
Attach 2 protective screens to the
outside of the window exhaust adapter.
Use 4 screws to attach the protective
screens onto the outside of the window
exhaust adapter.
4
Install 2 rain deflectors to the outside of
the window panel.
Line up the holes on the rain deflector
and the window panel. Use 8 bolts, 8
washers, 8 split-ring washers and 8 nuts
to attach the rain deflector onto the win-
dow panel.
5
Attach the window panel to the window
stool.
If the inner width of the window is less than
28" (718mm) wide.
(1) Remove the adjustment panel from
the window panel, and cut the window
panel to the same width as the window.
(2) Open the window sash and place the
window panel on the window stool
(3) Secure the window panel to the window
stool with 2 large wood screws.
Window exhaust adapter
Window panel
E-12
Foam seal A
Window panel
Inside
Cut
Window panel