Application Note
Step 4 – Transformer Construction Parameters
Enter: CORE, AE, LE, AL, VE, BOBBIN, AW, BW, MARGIN
Choose Core and Bobbin based on maximum output power.
TRANSFORMER CONSTRUCTION
61
PARAMETERS
62
CORE SELECTION
63
CORE
64
CORE CODE
65
AE
66
LE
67
AL
68
VE
69
BOBBIN
70
AW
71
BW
72
MARGIN
73
74
PRIMARY WINDING
75
NPRIMARY
76
BPEAK
77
BMAX
78
BAC
79
ALG
80
LG
81
LAYERS_PRIMARY
82
AWG_PRIMARY
83
OD_PRIMARY_INSULATED
84
OD_PRIMARY_BARE
85
CMA_PRIMARY
86
87
SECONDARY WINDING
88
NSECONDARY
89
AWG_SECONDARY
90
OD_SECONDARY_INSULATED
91
OD_SECONDARY_BARE
92
CMA_SECONDARY
93
94
BIAS WINDING
95
NBIAS
Figure 7.
Transformer Core and Construction Variables Section of InnoSwitch3 PIXLs Spreadsheet.
Core Type, CORE
By default, if the core type cell is left empty, the spreadsheet will
select the smallest commonly available core suitable for the
continuous (average) output power specified. Different core types
10
Rev. A 10/18
RM6
Info
4
6
The transformer windings may not fit: pick a
bigger core or bobbin and refer to the Transformer
RM6
Parameters tab for fit calculations
PC95RM06Z
Core code
37.00
mm^2
Core cross sectional area
29.20
mm
Core magnetic path length
2150
nH/turns^2
Ungapped core effective inductance
1090.0
mm^3
Core volume
B-RM06-V
Bobbin
15.52
mm^2
Window area of the bobbin
6.20
mm
Bobbin width
Safety margin width (Half the primary to
0.0
mm
secondary creepage distance)
77
Primary turns
3125
Gauss
Peak flux density
2844
Gauss
Maximum flux density
933
Gauss
AC flux density
140
nH/turns^2
Typical gapped core effective inductance
0.310
mm
Core gap length
4
Number of primary layers
30
AWG
Primary winding wire AWG
Primary winding wire outer diameter with
0.303
mm
insulation
Primary winding wire outer diameter without
0.255
mm
insulation
248
Cmil/A
Primary winding wire CMA
6
Secondary turns
19
AWG
Secondary winding wire AWG
Secondary winding wire outer diameter with
1.217
mm
insulation
Secondary winding wire outer diameter without
0.912
mm
insulation
216
Cmil/A
Secondary winding wire CMA
15
Bias turns
and sizes from the drop-down list are available to choose from if a
user-preferred core is not available, the grey override cells (AE, LE,
AL, VE, AW & BW) can be used to enter the core and bobbin
parameters directly from the manufacturer's data sheet.