Installation Conditions - Gaggenau RW 404 Operating And Installation Instructions

Table of Contents

Advertisement

Installation conditions

Installation location
The best installation location is a dry, well ventilated room.
The installation location should neither be exposed to
direct sunlight nor should it be near a heat source, such
as a stove, radiator, etc.
If installation next to a heat source is unavoidable, use a
suitable insulating plate or observe the following mini
mum distances to the heat source:
3
H
3 cm (1
/
'') to electric or gas stoves.
16
13
H
30 cm (11
/
'') to oil or coal stoves.
16
The floor in the installation location may not sag;
if necessary, reinforce the floor.
The power cord plug must be accessible after the
installation of the appliance.
Installation dimensions
Room temperature
The climatic class can be found on the rating plate.
It specifies the room temperatures at which the appliance
can be operated.
Climatic class
Permitted ambient temperature
SN
+50 °F ... 90 °F
N
+61 °F ... 90 °F
ST
+61 °F ... 100 °F (+16 °C ... 38 °C)
T
+61 °F ... 109 °F (+16 °C ... 43 °C)
SN ST
+50 °F ... 100 °F (+10 °C ... 38 °C)
The appliance is fully functional within the room tempera
ture limits of the specified climate class.
If an appliance of the climate class SN is operated at
colder room temperatures, damage to the appliance up
to a temperature of +41 °F (+5 °C) can be excluded.
(+10 °C ... 32 °C)
(+16 °C ... 32 °C)
7

Advertisement

Table of Contents
loading

Table of Contents