IMPORTANT!
The power supply cable must be connected by an authorised service person
DO NOT unscrew the screws fixing the cover plate behind the terminal block
1 Unhook the terminal board cover by inserting a
screwdriver into the two hooks at the base of the
block.
Feeder cable section
Use type HO5RR-F cable
MODEL CODE
CABLE SPECIFICATIONS
OR90S models
220-240 V 50Hz 3 x 2,5 mm2 *
** Connection with wall box connection.
!6
CONNECTION OF THE POWER SUPPLY CABLE
OR90SG6 MODELS ONLY
cable clamp
2 Unscrew the screw to open the cable clamp.
For OR90SCG6 and OR90SDG6 models, connect the
U bolts onto the terminal.
220-240V AC
1
L
2
3
4
N
5
PE
cable clamp
3 Connect the phase, neutral and earth wires to the
terminal board as shown. Strain the feeder cable and
block it with cable clamp. Screw clamp shut before
closing the main cover.
220-240V AC
L
N
PE
15