L16/24 GenSet Data

5L16/24
6L16/24
7L16/24
8L16/24
9L16/24
A
No. of Cyls.
5 (1,000 r/min)
5 (1,200 r/min)
6 (1,000 r/min)
6 (1,200 r/min)
7 (1,000 r/min)
7 (1,200 r/min)
8 (1,000 r/min)
8 (1,200 r/min)
9 (1,000 r/min)
9 (1,200 r/min)
P Free passage between the engines, width 600 mm and height 2,000 mm
Q Min. distance between engines: 1,800 mm
* Depending on alternator
** Weight incl. standard alternator (based on a Leroy Somer alternator)
All dimensions and masses are approximate and subject to change without prior notice.
Fig. 4.06.01: Power and outline of L16/24
MAN B&W S80MC/MC-C/ME-C, K80MC-C/ME-C, S70MC/MC-C/ME-C/ME-GI,
L70MC-C/ME-C, S65ME-C/ME-GI, S60MC/MC-C/ME-C/ME-GI/ME-B,
L60MC-C/ME-C, S50MC/MC-C/ME-C/ME-B, S46MC-C/ME-B, S42MC,
S40MC-C/ME-B, S35MC/MC-C/ME-B, L35MC, S26MC
Bore: 160 mm
1,200 r/min
Eng. kW
500
660
770
880
990
B
C
A (mm)
* B (mm)
2,751
1,400
2,751
1,400
3,026
1,490
3,026
1,490
3,501
1,585
3,501
1,585
3,776
1,680
3,776
1,680
4,151
1,680
4,151
1,680
Power layout
60 Hz
1,000 r/min
Gen. kW
Eng. kW
475
450
625
570
730
665
835
760
940
855
H
* C (mm)
4,151
4,151
4,516
4,516
5,086
5,086
5,456
5,456
5,731
5,731
MAN Diesel
Page 1 of 3
Stroke: 240 mm
50 Hz
Gen. kW
430
542
632
722
812
P
830
1000
Q
**Dry weight
H (mm)
GenSet (t)
2,457
9.5
2,457
9.5
2,457
10.5
2,457
10.5
2,457
11.4
2,457
11.4
2,495
12.4
2,457
12.4
2,495
13.1
2,495
13.1
4.06
178 23 031.0
178 33 874.3
198 42 054.5