Man B&W L35MC6-TII Project Manual page 232

Camshaft controlled two-stroke engines
Table of Contents

Advertisement

MAN B&W
Deaerating tank
øJ
øK
Diameter corresponding to
pipe diameter in engine room
Fig. 12.07.01: Deaerating tank, option: 4 46 640
LS 8412 AL
Level switch
Fig. 12.07.02: Deaerating tank, alarm device, option: 4 46 645
MAN B&W S50MC6, S50MC-C7, S50MEC7, S46MC-C7/8,
S46ME-B8, S42MC7, S40MC-C9, S40ME-B9, S35MC7,
S35MC-C9, S35ME-B9, L35MC6, S26MC6
øH
5
G
øI
178 06 279.2
Level switch float
Level switch float
in position for alarm
MAN Diesel
Deaerating tank dimensions
Tank size
Max. jacket water capacity
Max. nominal diameter
A
B
C
D
E
F
G
øH
øI
øJ
øK
ND: Nominal diameter
Working pressure is according to actual piping arrangement.
In order not to impede the rotation of water, the pipe connec-
tion must end flush with the tank, so that no internal edges are
protruding.
Alarm device
Level switch float
in normal position  no alarm
Page 2 of 2
0.05 m
3
120 m
/h
3
Dimensions in mm
125
600
125
5
150
300
910
250
300
320
ND 50
ND 32
Expansion tank
From deaerating tank
12.07
198 97 091.1
198 40 651.3

Hide quick links:

Advertisement

Table of Contents
loading