Siemens MOTOX BA 2510 Operating Instructions Manual page 21

Optional add-on units
Table of Contents

Advertisement

Coolant - oil
The use of oil as a coolant is possible in principle. Take into account that it has a significantly lower cooling capacity than
when water is used.
Siemens AG can calculate the cooling capacity on request.
9.2
Oil quantities and types of construction
NOTICE
Incorrect oil quantities damage the gearbox
The oil quantities in liters listed in the tables are guide values for changing the oil.
They are used, for example, for lubricant storage and procurement.
The precise values depend on the number of stages and transmission ratio of the gearbox.
Check the oil level before commissioning.
The type of construction designations are in accordance with IEC 60034-7 (Code I).
The gearbox must be operated only in the type of construction specified on the rating plate. This ensures that the correct
quantity of lubricant is provided.
Description of the symbols:
Ventilation
Checking the oil level of the bevel helical gearbox deviates from BA 2010.
Use the screw plug with marking A for types of construction
● V5-00 / H-05
● V1-00
● V3-00 / H-06
Use the screw plug with marking B for types of construction
● B3-00 / H-01
● B8-00 / H-02
● B5-01
● B5-03
Ventilation of the bevel helical gearbox deviates from BA 2010. Use the screw plug with marking C for types of construction
● B6-00
● B5-00 / H-04
BA 2510
A5E38121849A/RS-AB, 10/2016
Oil level
Oil drain
19