Siemens MOTOX BA 2510 Operating Instructions Manual page 14

Optional add-on units
Table of Contents

Advertisement

Figure 5-2
Surface to be sealed when mounting an IEC motor
Procedure
1. Clean the surfaces to be sealed on the motor and coupling lantern.
2. Coat the entire surface with an appropriate sealing compound.
3. Flange-mount the motor to the coupling lantern and secure it using the prescribed torque.
4. Apply a suitable protective coating to the interface and the entire geared motor to prevent corrosion.
The general tolerance for the tightening torque is 10 %. The tightening torque is based on a friction coefficient of μ = 0.14.
Table 5-1
Tightening torques for fastening bolts
Thread size
M4
M5
M6
M8
M10
M12
M16
M20
M24
M30
M36
6
Automatic regreasing device
The agitator flange and the mixer flange can be optionally supplied with an automatic regreasing device.
The automatic regreasing device can be disassembled in any position and can be used underwater.
12
Tightening torque for strength class
8.8
[Nm]
3
6
10
25
50
90
210
450
750
1 500
2 500
10.9
[Nm]
4
9
15
35
70
120
295
580
1 000
2 000
3 600
12.9
[Nm]
5
10
18
41
85
145
355
690
1 200
2 400
4 200