2.2
Lubrication
In normal operating conditions and with low loads, the lubrication of the bearings is sufficient for approximately 25,000 to
30,000 operating hours.
For higher loads due to speed and / or temperature, schedule regreasing at shorter intervals.
2.2.1
Regreasing intervals
The regreasing interval is valid for a temperature of +70 °C, measured on the surface of the housing in the vicinity of the
bearing.
Note
For temperatures above +70 °C, the regreasing interval must be reduced by half for each temperature increase of 15 K.
Note
For moderate shock loading and vibration, the regreasing interval must be reduced by 20 %.
For heavy loading, the regreasing interval must be reduced by half.
Regrease the bearing after the following number of operating hours.
Table 2-1
Regreasing intervals in operating hours for agitator flange
Output speed n
2
[rpm]
≤ 30
31 ... 50
51 ... 100
101 ... 150
151 ... 250
251 ... 400
2.2.2
Roller bearing grease
NOTICE
When regreasing do not mix greases with different soap bases
For regreasing, use lithium-saponified roller bearing grease NLGI 3/2.
Using a grease gun, inject the grease into the bearing point via the lubricating nipples provided.
The grease quantities listed in the table are guide values.
Table 2-2
Grease quantities for regreasing the agitator flange
Regreasing interval
After 6 months
After several years without operation
6
Operating hours for size
68
88
[h]
29 000
29 000
29 000
29 000
29 000
29 000
29 000
29 000
18 000
16 000
14 000
12 000
Grease quantity for regreasing for size
68
[g]
20
50
108
128
29 000
29 000
29 000
29 000
16 000
16 000
14 000
12 000
10 000
9 000
7 000
7 000
88
108
20
50
60
120
148
168
29 000
18 000
14 000
14 000
10 000
10 000
9 000
7 000
5 000
5 000
4 000
4 000
128
148
168
60
70
70
160
170
200
A5E38121849A/RS-AB, 10/2016