Siemens MOTOX BA 2510 Operating Instructions Manual page 15

Optional add-on units
Table of Contents

Advertisement

Lubrication time controller
Pressure generator
H
gas
2
Pressure piston
Transparent housing
Roller bearing grease
Container floor
Connection thread
Figure 6-1
Automatic regreasing device
Table 6-1
Technical data
Grease fill quantity
Adjustable lubrication time
Permissible ambient temperature
Maximum operating pressure
Pressure generator
Recommended storage temperature
Usage period
Weight including grease fill
Commissioning
CAUTION
Closed lubricator bursts
Overpressure will result if the lubricator is not opened and the grease channels are contaminated. At an overpressure of
approximately 5 bar, the lubricator will burst at the preset breaking point between the housing and the funnel.
Open the lubricator before commissioning.
Press fresh grease into blocked channels with a grease gun.
Note
Fill the lubricant channels and bearing with grease before installing the lubricator.
Procedure
1. Clean the area around the connection thread of the greasing point.
2. Use a knife to cut off the seal at the lubricator outlet, or remove the screw plugs.
BA 2510
A5E38121849A/RS-AB, 10/2016
125 ml
0 ... 12 months
-20° C ... +55° C
3 bar
Hydrogen gas generating cell
+20° C
Within 2 years of filling date
approx. 190 g
13