ProJet Hornet-III Instruction Manual page 23

Table of Contents

Advertisement

FAIL SAFE Settings Menu 3.4
FAILSAFE DELAY:
Time between error impulses and depressing to fail safe rpm (Menu FAILSAFE THRUST).
FAILSAFE TIMEOUT:
Engine will shut off, if there is no valid impulse recognized or the receiver is already in fail safe modus.
FAILSAFE THRUST:
When „FAILSAFE DELAY" is runned over, engine will decreased to the stored value.
Disabling FAIL SAFE function:
Fail safe function is disabled, if the value 0,0 sec. is entered.
AUXILIARY
Function as ON/OFF switch:
On/Off switch (Replacement for trimming):
The switch replaces trimming, switch ON = trimming ahead / switch OFF = trimming backward. Notice: using
switch the trimming has to be left at the max. position.
Smoker-Valve:
A smoker valve can be turned on and off. The valve is activated at 300°C and is automatically shut off below
300°C.
Radio control and ecu will connected on AUX-input patch cable. It is located directly below to the throttle
channel cable.
APPENDIX
FIRST START – NECESSERY SETTINGS
To use the ECU with a turbine some settings are necessary. Basic steps:
1.
MAX/IDLE-speed (Menu 1.1, 1.2)
2.
Pump voltage during start (Menu1.4)
3.
Adjustment radio control (Menu 2.1)
4.
Setting burner voltage (Menu 2.2)
5.
Adjustment temperature (Menu 2.2)
23