9.20 HEATING TIME
After fuel ignition the combustion chamber will be heated up for this adjusted time.
9.21 FUEL DELAY
After heating the starter will rise up slowly in adjusted time, without increasing pump voltage. (STATUS:
RAMP DELAY)
9.22 RAMP-UP TIME
Engine will increased to idle rpm in adjusted time. Thereby pump voltage will increase. Menu
VOLTAGE IDLE
9.23 RAISING PUMP VOLTAGE
To ignite fuel, the pump voltage will increased with this value.
9.24 PROPANE/BURNER SWITCH OFF SPEED
After exceeding the adjusted rpm the propane resp. the fuel supply will stop.
9.25 ACCELERATION CURVE
Choice of an acceleration curve (chapter functions and program flow).
9.26 DELAY CURVE
Choice of a delay curve (chapter functions and program flow).
9.30 RESET OPERATING COUNTER
Reset operating counter.
9.98 PUMP-OFFSET
To compensate fabricating tolerances adjust a normative-actual state of voltage of the pump power
amplifier. It is not allowed to change this value.
9.99 PRESETTING ENGINE TYPE
Used engine could be preset. The list of types is permanently expanded, ask your producer of your engine
about settings for your engine.