ProJet Hornet-III Instruction Manual page 14

Table of Contents

Advertisement

ERROR MESSAGES AUTO-CALIBRATION
FLAMEOUT DURING CALIBRATION
REASON: Temperature felt short of 250 degree during calibration-run.
EXPLANATION: Fuel supply interrupted -> User error
FELT SHOR T OF MIN. CALIBRATION RPM
REASON: Necessary rpm felt short of to ramp up engine
EXPLANATION: Disturbance at speed sensor (Light, electrical error), Fuel supply interrupted (Bubbles) -> User
error
ERROR DURING CALIBRATION
REASON: Calibrations rpm could not stabilized
EXPLANATION: Calibration time to fast (Menue 9.4), Fuel supply interrupted -> User error
CALIBRATION VOLTAGE EXCEEDED
REASON: Max calibration voltage was exceeded
EXPLANATION: Max. calibration voltage to low (Menu 9.5), Fuel supply interrupted , Pump broken (Loosing
power ) -> User error
Calculated fuel pump voltage too high
REASON: Necessary pump voltage exceeded the max. permitted voltage of the ecu to reach the max. rpm
(Menu 1.6)
EXPLANATION: The max. allowed fuel pump voltage exceeds the adjusted volte in pump max volt (Menue 1.6)
ERROR MESSAGES ENGINE RUN
FAILURE GASTHROTTLE PULSE
REASON: Break down throttle pulse during engine run,
EXPLANATION:
Disturbance at input signal of PPM receivers, Loosing contact at connection receiver/ecu,
Broken throttle-channel
FAILURE SPEEDSENSORSIGNAL
REASON: Speed-impulse fail
EXPLANATION: Bright light, Broken speedsensor,Disconnected speedsensor
MAX. RPM EXCEEDED
REASON: Exceeded max. rpm
EXPLANATION:
Wrong settings at control loop -> Overshot, Disturbance at speedsensors (Light, electrical
error,losing contact)
MIN RPM UNDERRUN
REASON: Minimum rpm felt short of