Miele EVS 6114 Operating And Installation Instructions page 31

Built-in vacuum sealing drawer
Table of Contents

Advertisement

Problem
The vacuuming process
takes longer than
expected.
The vacuum sealing bag
was not sealed early.
All sensors have gone
out. The glass lid will
not open.
There is still too much
air in the bag at the end
of the vacuuming
process.
After several
consecutive vacuuming
processes, the weld
seam is faulty/not
properly sealed.
Possible cause and remedy
The oil in the vacuum pump has become extremely
hot.
 Leave the drawer to cool for an hour before
starting another vacuuming process.
 When carrying out a number of consecutive
vacuuming processes, wait a minimum of
2 minutes between each process to prevent the oil
from overheating again.
The required vacuum (vacuum level 1) for sealing a
bag was not achieved.
 Touch the  sensor again or repeatedly until the
vacuuming process ends and the bag is sealed.
There was an interruption to the power supply during
the vacuuming process. The vacuum chamber is still
under pressure so the glass lid cannot be opened.
Do not in any circumstances try to force the glass
lid open or use tools to open it.
 When the power supply is restored, the glass lid
can be opened again after initialisation (all sensors
and controls light up).
 Start the vacuuming process again if necessary.
The vacuum level was too low.
 Start the vacuuming process again with a new bag
and a higher vacuum level.
The vacuum sealing bag is too big for the food to be
vacuumed.
 Use a new smaller bag or cut a larger bag to fit the
size of the food.
 Start the vacuuming process again with a higher
vacuum level if necessary.
The sealing bar has overheated.
 Wait a minimum of 2 minutes between individual
vacuuming processes to avoid the sealing bar
overheating again.
Problem solving guide
31