Ratings And Characteristics - Omron H5S Instruction Manual

Digital time switch
Hide thumbs Also See for H5S:
Table of Contents

Advertisement

4. Ratings and Characteristics

Supply voltage
Operating voltage range
Power consumption (*1)
Number of circuits
Circuit
Resistive (cos =1)
Inductive
Ambient operating temperature
Ambient operating humidity
Storage temperature
Total error (*3)
Cyclic error (*4)
Memory protection
Weight
Cycle length
Minimum cycle length
Pulse width
Weekly programs (*5)
Yearly program capacity
Yearly holiday setting capacity
Installation environment
Altitude
Mechanical durability
Malfunction durability
Mechanical durability
Malfunction durability
Approvals
*1 At 264 VAC, 60Hz for AC-type or 28.8 VDC for DC-type
*2 A current of 15 A can be passed through each output.
The current as sum of 2 outputs varies depending on the
ambient air temperature. The right hand diagram shows
the derating curve.
*3 The total error including the repeat accuracy, setting error,
variation due to voltage change, and variation due to
temperature change is ±0.01%±0.05 s max.
*4 Refer to "9. Time accuracy" in the Operation.
*5 Number of steps used for each weekly operation is as
shown below.
Timer operation:
Pulse-output operation :
Cyclic operation:
*6 Program capacity when no season is set :
*7 Program capacity when seasons are set :
Weekly 2 chnls
H5S-WB2(D)
H5S-WFB2(D)
100 to 240 VAC 50/60 Hz : Models without "D" in model number
24 VDC : Models with "D" in model number
Approx. 2.9 VA (AC)
Approx. 0.8 W (DC)
SPST-NO X 2 circuits (independent)
Separated from power circuit (no-voltage)
15 A, 250 VAC (*2)
10 A, 250 VAC (cos =0.7)
–10 to 55 ˚C (with no icing or condensation)
25 to 85% (with no icing or condensation)
–25 to 65 ˚C (with no icing or condensation)
±15s per month (at 25˚C)
1 week
1 to 59 s (in seconds) or 1 to 60 min (in minutes)
40 steps/chnl
Over-voltage Category II, pollution degree 2 (as per IEC61010-1)
10 to 55 Hz, 0.75 mm double amplitude
10 to 55 Hz, 0.25 mm double amplitude
2 steps
1 step
4 steps
Yearly 2 chnls
H5S-YB2(D)-X
H5S-YFB2(D)-X
85 to 110% of rated voltage (AC)
85 to 120% of rated voltage (DC)
Approx. 3.2 VA (AC)
Approx. 0.9 W (DC)
±0.01% ±0.05s max.
±15s per month (at –10 to 45 ˚C)
5 years min. (at 25˚C)
Approx. 200 g
1 year (with the built-in calendar to year 2099)
1 min
48 steps/chnl (*6)
24 steps/chnl (*7)
16 steps (4 times)/chnl
16 times
2,000 m max.
300m/s
100m/s
cURus UL 508 / CSA C 22.2 No.14
EN60730-2-7
VDE0106/part100
Section 6-5 in the Operation
Section 6-5 in the Operation
- 66 -
Yearly 4 chnls
H5S-YB4(D)-X
H5S-YFB4(D)-X
Approx. 3.5 VA (AC)
Approx. 1.0 W (DC)
SPST-NO X 4 circuit (independent)
3A, 250VAC
2A, 250VAC (cos =0.4)
48 steps/chnl (*6)
12 steps/chnl (*7)
16 steps (4 times)/chnl
16 times
2
2
30
20
0
-10 0
25
Ambient air temperature(˚C)
50 55