6-6-3. F3: Total Time Alarm

The alarm value can be set for the total time. (
Setting range
0.0 to 99990.0 h
Time is set in 10 hour unit.
The default is 0.0h (The alarm indicator output is off).
Setting
The setting is made in F3 (total time alarm) of initial setting mode.
TIME ADJ
Press
setting mode to enter initial setting mode.
Give short presses on
move to the F3 display.
Alarm value setting display appears
automatically in 2 s after entering F3.
Press
or
h
(Pressing HOLIDAY/
decrements the value of the Key that was last pressed.)
h
: increments in 1,000 hour unit.
: increments in 10 hour unit.
m
Press
WRITE
(After a one second pause, the screen returns to the initial display of F3.)
Set the Mode Switch to RUN.
Note
• F3 is displayed only when " totl" is selected in F2 (input selection).
• Alarm (
indicator) will be displayed when either the total time (F3) or the
total count (F4) reaches the set alarm value.
• If an alarm value for the total time is set to 0, the alarm indicator does not appear.
• To leave initial setting mode, press
• If
is pressed again before confirming the setting, the setting is cancelled.
TIME ADJ
for 3 s or more in program
TIME ADJ
to set an alarm value.
m
or
SELECT PRGM/
to confirm the setting.
Weekly
2 chnls
The
and
TIME ADJ
for 3 s or more.
- 50 -
Yearly
Yearly
2 chnls
4 chnls
color indicates flashing.
6-1)