Aaeon AEC-6930 Manual page 51

Fanless embedded controller
Table of Contents

Advertisement

E m b e d d e d C o n t r o l l e r
1
WDTOUT10_OINV
0
STS_WDTOUT10
WDTOUT Control Register – Index 35h
Power-on default [7:0] =0000_0000b
Bit
Name
7
WDT10_ENABLE
6-0
WD1_PTIME
Appendix A Programming the Watchdog Timer A-4
WDTOUT10# output level inverting.
When write 1, the output pin will be
inverted. Default is low active when time
is out
Indicate WDTOUT10 is occurred. Write
1 to clear this bit. Writing 0 is invalid.
Description
Enable WDTOUT10 Output Timer. If set to
1, the WDTOUT10 timer will be started.
When WDTOUT10# is asserted, low pulse
is occurred.
WDTOUT10 Pre-counter time in second.
000_0000b – 0 second (Default)
000_0001b – 1 second
000_0010b – 2 seconds
:
111_1111b – 127 seconds