User Passwords Menu

5.7.1
Change Admin Password – Change the password for the Admin level user. This string can be
between 8 and 30 alphanumeric characters.
Change Guest Password – Change the password for the Guest level user. This string can be
between 8 and 30 alphanumeric characters. This password can only be changed when logged in
as the admin user.
Change Integrator Password – Change the password for the Integrator level user. This string
can be between 8 and 30 alphanumeric characters. This password can only be changed when
logged in as the admin user.
NOTE
It is recommended to change the default value of the passwords for security. However, once
passwords have been changed, they can never return to the default values unless the radio is
sent back to GE MDS for service.

Console/Telnet Lockout Security

TD220MAX release 1.2.15 introduces a lockout on serial and telnet console logins after repeated
attempts fail. If an invalid login attempt is repeated 3 times on either console type, the console will no
longer display the login prompt for 5 minutes.
During this time, both serial and Telnet console logins are disabled (no matter which console was being
attacked) but existing console sessions will operate normally. If SNMP traps are enabled and/or a Syslog
server is configured, events recording the lockout will be sent to alert personnel to this possible attack.
After 5 minutes, both serial and Telnet consoles present the login prompt once again.