MPPES English – Proportional pressure regulating valve MPPES Documentation on the product For all available product documentation è www.festo.com/pk Control sections and connections Compressed air supply port Electrical connection (pressure input) Through holes Air supply port (pressure output) for fastening...
MPPES-..In this way you will avoid increased tolerances in the output pressure (for further information refer to the EMC specifications in the Technical data chapter). Festo – MPPES – 2018-01f English...
Observe the warnings and instructions – on the product Fig. 4 – in these operating instructions. Use the product in its original status, without any unauthorised product modifications. Festo – MPPES – 2018-01f English...
A distinction is made between the following valve variants (è Tab. 1). Designation on the rating plate MPPES-…-010 MPPES-…-420 Designation Voltage variant Current variant Electrical setpoint value DC 0 … 10 V 4 … 20 mA Tab. 1 Festo – MPPES – 2018-01f English...
Page 7
You can then guarantee that the specified protection class IP65 and EMC are fulfilled. Note Make sure that the cables are laid as follows: – not squashed – not bent – not stretched (è Fig. 8). Fig. 7 Fig. 8 Festo – MPPES – 2018-01f English...
Page 8
– Grey Actual value - Actual value - Pink output output DC 0 … 10 V 4 … 20 mA DC 24 V supply voltage Ground actual value Blue 1) Internally connected Tab. 2 Festo – MPPES – 2018-01f English...
Page 9
– current variant a current measuring device (ammeter). measuring device The actual electrical value can be tracked on the display of the meas uring device. This changes proportional to the pressure curve at port Fig. 14 Ammeter Festo – MPPES – 2018-01f English...
Disassembly and repair On disassembly: Note Switch off the following power: – compressed air – voltage supply Maintenance and care Clean the MPPES-... with soap suds only, max. +60 °C. Festo – MPPES – 2018-01f English...
(è Technical data). MPPES-... defective Return the MPPES-... to Festo Flow rate too low Restriction of the flow cross section Use an alternative connection due to connection technology (swivel fittings, silencer too small) Tab. 5 Festo – MPPES – 2018-01f English...
2) The device is intended for use in an industrial environment. Outside of industrial environments, e.g. in commercial and mixed-res idential areas, actions to suppress interference may have to be taken. 3) Only when using connecting cable from Festo. Tab. 6...
Page 13
Nominal flow rate 540 l/min. 2500 l/min. 8500 l/min. 3.6 } 3 with p = 8 bar at 1 Pressure ranges Permissible supply pressure: max. 8 bar control range: 0 … 6 bar Tab. 10 Festo – MPPES – 2018-01f English...
Page 14
Dependent on special adaptation selected 1 bar) Pressure ranges Permissible supply pressure: max. (P + 1) bar (with P 1 bar) max. (P + 2) bar (with P Permissible supply pressure: P ... P Tab. 12 Festo – MPPES – 2018-01f English...
Page 16
Copyright: Festo AG & Co. KG Ruiter Straße 82 73734 Esslingen Germany Phone: +49 711 347-0 Fax: +49 711 347-2144 Reproduction, distribution or sale of this document or communica E-mail: tion of its contents to others without express authorization is service_international@festo.com...