Let the product flow for a few seconds. Then close the recir-
culation tap. The pump will continue to work until the product
will fill the high pressure flexible hose up to the gun, then it
will stop.
Should the cycle speed be too high, decrease the feeding
pressure or slightly close the air tap (G4). Set the minimum
pressure necessary for the operation.
At the end of the work, stop the pump in the lower position
in order to prevent the product to dry on the piston and to
damage the gaskets.

ADJUSTING THE SPRAYING JET

Slowly turn clockwise the pressure adjustment knob until
the suitable value able to grant a proper atomization of the
product is reached.
An inconstant spray, slightly marked on the sides, might indi-
cate a too low pressure. On the contrary a too high pressure
might cause mist (overspray) and product dispersion.
Do not spray without the contemporaneous advancement of
the gun (right-left) in order to avoid an anomalous thickness
of the paint.
Always proceed with regular and parallel passages.
Keep a constant distance (25/30 cm) between the nozzle and
the support to be sprayed and keep yourself perpendicular
to it.
Avoid to work with maximum pressure.
NEVER direct the gun towards yourself or anyone
else.
Getting in touch with the jet might cause serious
wounds. In case of wounds derived by the gun jet,
immediatly provide for medical assistance speci-
fying the product you were using.
Recirculation-safety valve: during the operation
at the maximum pressure availble, when releasing
the gun trigger, you can assist to brisk pressure
increasings. In this case the recirculation-safety
valve automatically opens, discharging part of the
product from the recirculation hose. It then closes
in oder to set the previous working conditions.
VEGA 23:1
CLEANING AT THE END OF
H H
THE WORK
Remove the suction (H1) and the recirculation hoses (H2)
from the product container (H3) by going on spraying (H4),
until the pump is completely empty.
H2
H1
H4
Plunge the suction (H5) and the recirculation hoses (H6)
in the thinner container (H7). Set pressure to the mimimum
and by keeping the nozzle below the thinner level in the
container, spray until the thinner has been recycled during
three or five minutes.