The appliance must not be installed:
• With the blowing towards a permanent or temporary obstacle (awning, brushwood, etc.) less than 5 metres away,
• Within range of water or mud jets, sprays or run-off (take the effect of the wind into account),
• Near a heat source or flammable gas,
• Near high-frequency equipment,
• In a location where it would be subject to snow build-up,
• In a location where it might be flooded by the condensates produced by the appliance when operating.
Tip: reduce any noise annoyance from your heat pump
• Do not install it under or towards a window.
• Do not tilt it towards your neighbours.
• Install it in an open space (sound waves are reflected on surfaces).
• Install an acoustic screen around the heat pump, respecting the distances (see diagram § «1.2 I Hydraulic
connections»).
• Install 50 cm of flexible PVC pipe at the heat pump water inlet and outlet to absorb vibrations.
• Increase the filtration time by 50% and activate "silence" mode. The heat pump will run for longer
with less power, but much more quietly and with an improved COP (energy savings). «Silence» mode is
particularly well suited for maintaining the water temperature once the setpoint temperature has been
reached.
1.1.1 Setting up the device
• Use straps (not supplied) to lift the device to prevent damage during installation.
6