  • Page 1 Cooker hood Instruction manual Model No.:FAL-45-SQS...
  • Page 2 Page 1 (Inside) Please be careful when removing and installing the Island installation Brackets and Stainless Steel chimneys. The Stain Less steel chimneys contains sharp edges and can possibly lead to cuts. Generally asked Questions and Answers: 1. Q: My extractor fan is not extracting A: before logging a service call please ensure the installation on your extractor fans was done properly to avoid a service call out fee charge.
  • Page 3 You can also download it from www.falco.co.za 7. Q: How often do I have to replace my filters? A: With daily use we recommend that you replace your charcoal filters every 6 months. Your aluminium filters can be cleaned in luke warm water and dishwashing liquid.
  • Page 4 11. Q: Why is there rust marks on my extractor? A: Stainless steel can rust if cleaned with abrasive cleaners. The chemicals inside abrasive cleaners react with the stainless steel and the result will be rust. There are many day to day cleaning products in our kitchens that are abrasive cleaners and unknown to the consumer.
  • Page 5 A: Full range of spares are available from Lategan & Van Biljoens in Pretoria. www.appliancesspares.co.za 15. Q: What is the diameter of my ducting hose? A: 150mm 16. Q: More Queries? A: Please email any queries to: christie@falco.co.za, Tel: 011 454 6423/4314. Spares can be viewed and ordered online: www.appliancespares.co.za...
  • Page 6 NOTICE 1. Thank you for choosing our cooker hood. Please read the instruction manual carefully before use. 2. The installation work must be undertaken by a qualified and competent fitter. 3. The manufacturer disclaims all liability for any damage or injury caused as a result of not following instructions for installation contained in the following text.
  • Page 7 Installation 1. The cooker hoods should be placed at a distance of 65-75cm from the cooking surface for best effect. See Pic 1. 2. To install onto the wall every 100mm drill 3 holes of Ø8mm on a suitable place in line with the hook on the hood. 3.
  • Page 8 Notice of Installation 1. Before installation, please ensure the area is clean to avoid suction of the remaining bits of broken wood and dust. 2. It cannot share the same air ventilation tube with other appliance such as gas tube, warmer tube, and hot wind tube. 3....
  • Page 9 Operation Electronic button 1. Push the low button, the indicating light on, and the motor runs at low speed. Push it again and the motor will stop. 2. Push the middle button, the indicating light on, and the motor runs at mid speed.Push it again and the motor will stop 3.
  • Page 10 Abnormity and Solution Fault Cause Solution The leaf blocked Get rid of the blocking The capacitor damaged Replace capacitor Light on, but motor does not work The motor jammed bearing Replace motor damaged The internal with of motor off or Replace motor a bad smell from the motor Beside the above mentioned, check the following:...