1)
Problem
The filter is clogged.
Too high volume of the load.
Drying cycle
The laundry not spun sufficiently.
5)
too long
Very high room temperature - this is not
the appliance malfunction.
1) If there is an error message on the display (e.g. E51): Turn the tumble dryer off and on. Make a selection of the
new programme. Push the Start/Pause button. Does not operate? - contact the service centre and give the error
code.
2) follow the programme description — see PROGRAMMES chapter
3) see CARE AND CLEANING chapter
4) see section WATER HARDNESS in HINTS AND TIPS chapter
5) Note: After maximum 5 hours the drying cycle ends automatically (see Drying cycle complete section).
DRUM INTERNAL LAMP
This appliance has an internal lamp that
comes on when you open the door and
goes off when the door is closed.
Warning! Do not look directly into the
beam of the lamp.

TECHNICAL INFORMATION

height x width x depth
drum volume
maximum depth with the load door opened
maximum width with the load door opened
adjustable height
the appliance weight
maximum load volume
voltage
frequency
necessary fuse
total power
energy efficiency class
energy consumption kWh/cycle
annual energy consumption
type of use
permitted ambient temperature
1) 8 kg of cotton, centrifuged at 1000 rpm with reference to EN 61121

INSTALLATION

APPLIANCE POSITIONING
• The tumble dryer must be installed in a
clean position, where dirt does not col-
lect.
Possible cause
1)
Clean the filter.
Obey the maximum load volume.
Spin correctly the laundry.
If possible, lower the room temperature.
Important! To replace the internal lamp,
contact the service centre.
Disconnect the mains plug from the mains
socket before the replacement of the inter-
nal lamp.
850 x 600 x 600 mm (maximal 640 mm)
118 l
1090 mm
950 mm
850 mm (+ 15 mm - feet regulation)
56 kg
8 kg
230 V
50 Hz
4 A
800 W
A
1,92 kWh
108,3 kWh
Domestic
+ 5°C to + 35°C
• Air must flow freely around the appliance.
Make sure that the front airflow slots in
the bottom of the appliance are not
blocked .