Technical Information; Installation - Electrolux TW L4 E User Manual

Hide thumbs Also See for TW L4 E:
Table of Contents

Advertisement

Available languages

Available languages

40 electrolux
3) see CARE AND CLEANING chapter
4) see section WATER HARDNESS in HINTS AND TIPS chapter
5) Note: After maximum 5 hours the drying cycle ends automatically (see Drying cycle complete section).

TECHNICAL INFORMATION

height x width x depth
drum volume
maximum depth with the load door opened
maximum width with the load door opened
adjustable height
the appliance weight
maximum load volume
voltage
frequency
necessary fuse
total power
energy efficiency class
energy consumption kWh/cycle
annual energy consumption
type of use
permitted ambient temperature
1) 7 kg of cotton, centrifuged at 1000 rpm with reference to EN 61121

INSTALLATION

APPLIANCE POSITIONING
• The tumble dryer must be installed in a
clean position, where dirt does not col-
lect.
• Air must flow freely around the appliance.
Make sure that the front airflow slots in
the bottom of the appliance are not
blocked .
• To keep vibration and noise at the mini-
mum, when the tumble dryer operates, it
must be put on a stable and flat surface.
• When the appliance is put in its perma-
nent position, check if is fully level with
the aid of a spirit level. If it is not, adjust
the feet until it is.
• Do not remove the feet. Do not decrease
the floor clearance through thick carpets,
bar of wood or equivalent. This can in-
crease the heat which can cause interfer-
ence with the operation of the appliance.
Important!
850 x 600 x 600 mm (maximal 640 mm)
118 l
1090 mm
950 mm
850 mm (+ 15 mm - feet regulation)
56 kg
7 kg
230 V
50 Hz
4 A
800 W
A
1)
1,85 kWh
121,8 kWh
Domestic
+ 5°C to + 35°C
• The temperature of the hot air which oc-
• When the tumble dryer operates, the
• If it is necessary to move the appliance, it
• The appliance must not be installed be-
It is possible to adjust the height of the tum-
ble dryer. To do that adjust the feet (see
picture).
curs in the tumble dryer can increase to
60 °C. The appliance must not be instal-
led on the floor which is not resistant to
high temperatures.
room temperature must not be lower
than +5 °C and higher than +35 °C. This
can cause unwanted effect on the per-
formance of the appliance.
must be moved vertically.
hind a lockable door, a sliding door, a
door with a hinge on the opposite side to
that of the appliance in such a way that a
full opening of the tumble dryer is restric-
ted.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents