Page 2
Instruction Manual Ultrasonic Material Thick ness Gauge Thank you for buying a SAUTER digital Ultrasonic Thickness Gauge. We hope you are pleased with your high quality Thickness Gauge with its big functional range. If you have any queries, wishes or helpful suggestions, do not hesitate to call our service number.
Page 3
Sound velocity: 500 to 9000m/s Power supply: 4×1.5V AA (UM-3) battery Operating conditions: Temperature: 0 to 50°C; Humidity: <80% Size: 160×68×32mm (5.5×2.8×1.2inch) Weight: about 208g (not including batteries) Accessories: Carrying case Operation manual Ultrasonic sensor Ultrasonic coupling gel 4x 1.5V AA batteries TB-US-BA-e-1713...
`cd` is the abbreviation for `code` and `xx` is a number among 0.1 and 11 that stands for the material to be measured as shown in the scale below. `xxxx` is a 4-digit number describing the sound velocity of the material defined by the user. The `cdxx` material relationship is as follows: TB-US-BA-e-1713...
Page 5
On the display appears `0`. 5 Calibration 5a) A little oil has to be dropped on the base plate 3-12. 5b The calibration key 3-8 has to be pressed and `CAL` appears on the display. `CAL` is the abbreviation for calibration. TB-US-BA-e-1713...
Page 6
If velocity of a special material is known, it is easy to measure the material thickness by means of step 7b) 7c) Measuring of coatings and materials with an unknown thickness A test material of known thickness has to be selected. TB-US-BA-e-1713...
Page 7
8c) Batteries have to be installed, paying carefully attention to polarity. 8d) If the instrument is not in use for an extended period, batteries have to be re- moved. Annotation: To have a look at the CE Declaration of Conformity, please click onto the following link: https://www.kern-sohn.com/shop/de/DOWNLOADS/ TB-US-BA-e-1713...