Further Information; Recommendations For Twisted Pair Cables; Transmission Of Kvm Data - Guntermann & Drunck DL-DVI-Vision-CAT series Installation And Operating Manual

Table of Contents

Advertisement

Available languages

Available languages

Further information

Recommendations for twisted pair cables

Both the computer module and the user module provide
transmit the following data between the modules.
keyboard, video, mouse, audio, RS232, USB 2.0 (only
 Transmission:
 USB 2.0 Trans.:
USB 2.0 signals (only
The following paragraphs give you recommendations regarding the use of specific
twisted pair cables.
NOTE:
Several segments of a cable connection can be connected with patch panels
and connection ports.
It is, however, not permitted to connect active components such as network
switches, hubs or repeaters.

Transmission of KVM data

The signals keyboard, video, mouse, audio, RS232 and USB 2.0 (only
DL-DVI-Vision
system are transmitted via category 5e (or better) twisted pair cables.
Depending on the wire gauge and the type of twisted pair cable, the following dis-
tances can be bridged between computer module and user module.
Wire gauge
Cable type
AWG 22
Installation cable
AWG 24
Installation cable
AWG 26
Patch cable
The following cables achieved the best results during test operation:
 up to 140 metres:
Kerpen MegaLine ® G12-150 S/F (AWG 22)
Dätwyler uninet ® 5502 S-STP (AWG 24)
 up to 100 metres:
 up to 80 metres:
Dätwyler uninet ® 7702 Flex (AWG24)
Transmission
ARU2
variant)
Category
5e, 6 or 7
5e, 6 or 7
5e, 6 or 7
G&D DL-DVI-Vision-CAT · 48
Further information
interfaces to
variant)
ARU
variant) of the
ARU
Recommendation
up to 140 m
up to 100 m
up to 80 m

Advertisement

Chapters

Table of Contents
loading