I
: This manual contains assembly rules, installation steps, guidelines, use and maintenance
mportant
instructions for the MAGNUM 82028, 82036, 82042 & 82048 fireplaces and the DM chimney system, and Fire-Lite
Application with the ECO-STEEL & ECOSTEEL+ Chimney System. This manual must become the property of and
be reviewed by all current and future users of this product. It is the responsibility of the general contractor and
the installer of this product to ensure that the instructions in this manual are followed exactly and that any al-
lowed gas log appliance used in this product be installed in strict accordance with NFPA 58, NFPA 54/ANSI Z223.1
and the gas log manufacturer's explicit installation, sizing and operation instructions. It is the responsibility of the
general contractor to provide adequate clearances from all firebox surfaces as specified in this manual.
Be Sure to Read Entire Manual Before Beginning Construction.
Contents of this manual may change without prior notification.
SBCCI NO. 9626
NYC-MEA 241-90-E
ICC Report NO. ESR-2316
LA RR NO. 25483
IBC 2006, IRC 2006, IMC 2006
THESE FIREPLACES ARE DESIGNED for USE with:
Solid Wood Logs, PROPANE (LP) or NATURAL GAS (NG), ONLY
THIS MANUAL CAN ONLY BE REPRODUCED IN ITS ENTIRETY
MAGNUM
®
with Fire-Lite Application
and DM Chimney System
MAGNUM Models 82028, 82036, 82042 & 82048
A PRODUCT OF EARTHCORE INDUSTRIES, LLC.
INSTALLER: Leave this manual with the fireplace
CONSUMER: Retain this manual for future reference
DO NOT install the MAGNUM Series Fireplace in a manufactured
home or mobile home or recreational vehicle.
Fireplace
®
Listing Services Report NO. 3159656MID-008 & 3082504-T1
Issued: September 2018
Revision: 002
©2018 Earthcore Industries, LLC

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MAGNUM 82028 and is the answer not in the manual?

Questions and answers

Summary of Contents for Isokern MAGNUM 82028

  • Page 1 : This manual contains assembly rules, installation steps, guidelines, use and maintenance mportant instructions for the MAGNUM 82028, 82036, 82042 & 82048 fireplaces and the DM chimney system, and Fire-Lite Application with the ECO-STEEL & ECOSTEEL+ Chimney System. This manual must become the property of and be reviewed by all current and future users of this product.
  • Page 2: Table Of Contents

    Earthcore Industries MAGNUM Series Fireplace Table of Contents General Information ........... 3-4 DM Chimney Crown Caps .......... 37 Safety Instructions ............. 5-6 DM Chimney Terminations ......... 38 Warnock-Hersey Listing Label ........7 Eco-Steel/Eco-steel+ Metal Chimney Flue ....39 MAGNUM 28 - Firebox Dimensions ......8 Component List - ECO-STEEL Chimney .....
  • Page 3: General Information

    Close attention should be paid to each component group’s specifications and installation requirements as described in this manual. Recommended minimum overall height for the Isokern fireplace, DM, ECO-STEEL & ECO- STEEL + chimney system for an indoor application is 18’-0” when the chimney is straight and 21’-0” when a chimney is offset.
  • Page 4: General Information

    Isokern is not responsible for other construction work around the fireplace unit. We recommend (1) 4" outside air kit for MAGNUM 28, 36, 42, and 48.
  • Page 5: Safety Instructions

    Earthcore Industries MAGNUM Series Fireplace Safety Instructions WARNING: This product contains or generates chemicals known to the state of California to cause cancer or birth defects or other reproductive harm. IMPORTANT: Read this owner’s manual carefully and completely before trying to assemble, oper- ate or service this fireplace.
  • Page 6 12. When in doubt about a component’s usability - has visible or suspected physical damage - con- sult your Isokern distributor or authorized Isokern representative for advice. 13. Modification to MAGNUM components not mentioned in this manual may void claims, listings and approvals and could result in an unsafe and potentially dangerous installation.
  • Page 7: Warnock-Hersey Listing Label

    TO PRINT, THANK YOU Isokern Fireplace and Chimney Systems are tested and listed to UL standards: UL 127 , ULC S610, and UL 103HT. The listing label shown in Figure 1 above outlines the listed clearances to combustibles and indicates that the units are suitable for use with solid fuel or listed gas appliances.
  • Page 8: Magnum 28 - Firebox Dimensions

    MAGNUM 28 (82028) CAUTION: When using the Isokern brick ledge, it is required that the firebox/smoke dome assembly include the placement of a 4" x 4" x 3/8" minimum steel angle across the firebox opening. (See page 39 for "Structural Information" for details regarding specification and placement of steel angles in fireplaces.)
  • Page 9: Component List - Magnum 28

    Earthcore Industries MAGNUM Series Fireplace Component List - MAGNUM 28 (82028) Component Part# Description 7 1/2” Isokern MAGNUM M91CC Base Plate 35 1/2” 4” Isokern MAGNUM Smoke Dome (QTY. 2) 16” 32 1/2” 2 3/4” 25¼” Isokern MAGNUM Side Sloping (Qty. 2) 16”...
  • Page 10: Magnum 36 - Firebox Dimensions

    MAGNUM 36 (82036) CAUTION: When using the Isokern brick ledge, it is required that the firebox/smoke dome assembly include the placement of a 4" x 4" x 3/8" minimum steel angle across the firebox opening. (See page 39 for "Structural Information" for details regarding specification and placement of steel angles in fireplaces.)
  • Page 11: Component List - Magnum 36

    Earthcore Industries MAGNUM Series Fireplace Component List - MAGNUM 36 (82036) Component Part# Description 28” Isokern MAGNUM Base Plate 43” 4” Isokern MAGNUM Smoke Dome (QTY. 2) 16” 43” 3” 25¼” Isokern MAGNUM Side Sloping (Qty. 2) 16” 8” 28”...
  • Page 12: Magnum 42 - Firebox Dimensions

    MAGNUM 42 (82042) CAUTION: When using the Isokern brick ledge, it is required that the firebox/smoke dome assembly include the placement of a 4" x 4" x 3/8" minimum steel angle across the firebox opening. (See page 39 for "Structural Information" for details regarding specification and placement of steel angles in fireplaces.)
  • Page 13: Component List - Magnum 42

    Earthcore Industries MAGNUM Series Fireplace Component List - MAGNUM 42 (82042) Component Part# Description 28” Isokern MAGNUM Base Plate 49” 4” Isokern MAGNUM Smoke Dome (QTY. 2) 16” 43” 3” 25¼” Isokern MAGNUM Side Sloping (Qty. 2) 16” 8” 28”...
  • Page 14: Magnum 48 - Firebox Dimensions

    MAGNUM 48 (82048) CAUTION: When using the Isokern brick ledge, it is required that the firebox/smoke dome assembly include the placement of a 4" x 4" x 3/8" minimum steel angle across the firebox opening. (See page 39 for "Structural Information" for details regarding specification and placement of steel angles in fireplaces.)
  • Page 15: Component List - Magnum 48

    Earthcore Industries MAGNUM Series Fireplace Component List - MAGNUM 48 (82048) Component Part# Description 28” Isokern MAGNUM Base Plate 53” 4” Isokern MAGNUM Smoke Dome (QTY. 2) 16” 53” 3” 25¼” Isokern MAGNUM Side Sloping (Qty. 2) 16” 8” 28”...
  • Page 16: Required Clearance To Combustibles

    (as determined through testing and as stated by the manufacturer) are not maintained due to construction subsequent to the installation of the Isokern unit. It is the general contractor’s responsibility to assure that listed clearances to combustible framing and to insulation are maintained throughout the construction of the project subsequent to the installation of the Isokern unit.
  • Page 17: Required Clearance To Combustibles

    EXCEPTION: If insulation is used in walls surrounding the fireplace, insulation may be installed behind sheathing of gypsum board, plywood, particle board or other material on the side facing the Isokern. The facing material cannot be within 1½” to the fireplace side walls.
  • Page 18: Supporting Floor System

    1. Slab on grade: standard residential, minimum four inch (4”) thick, 2500 psi concrete foundation on properly compacted fill. This type foundation can support Isokern installations up to thirty feet (30’)* overall height without additional structural support. (brick ledge installations not included) (Figure 5).
  • Page 19: Fire-Lite Application

    (0”) clearance. Gypsum board, plywood, particle board, or other material can be used on the side facing the Isokern (Figure 8). IMPORTANT: The Fire-Lite Application is designed, tested and approved for installation at a minimum of four inches (4”) above combustible floor systems per the installation...
  • Page 20 Use of Insboard cut-out underneath the Fire-Lite stand is still an accepted installation practice (Figure 9). All Fire-Lite Application of the Isokern fireplace result in the finished fire brick floor of the firebox being at least eight inches (8½”)* above the combustible floor system (Figure 9).
  • Page 21 Earthcore Industries MAGNUM Series Fireplace Fire-Lite Application Recessed Fire-Lite: If the design preference is for a flush hearth Fire-Lite application (floor of the fireplace at the same level the room’s floor), with advanced planning, the metal stand can be lowered, set and attached to the joist system (Figure 10).
  • Page 22: Rough Framing Dimensions

    Earthcore Industries MAGNUM Series Fireplace Rough Framing Dimensions Typical Installation Framing Dimensions FIGURE 12 MAGNUM Width - A Height - B Depth - C Model 28 38 ½” 61 ½” 29 ½” Model 36 46” 71” 29 ½” Model 42 52”...
  • Page 23: General Assembly Instructions

    Apply a thin layer of Earthcore Adhesive to the area and set base plate in the mortar (Figure 14). Earthcore Adhesive is then squeezed from a grout bag onto the contact surfaces of the Isokern components as they Earthcore are fitted together.
  • Page 24 2. Set the first course of the firebox side walls and backwalls into place (Figures 18 & 19). NOTE: It may be convenient to dry set the first course of side walls and backwalls into place on the Isokern base plate, and then trace their position on the base plate with a pencil.
  • Page 25 NOTE: If you are using DM Chimney or DM Chimney with a brick ledge. a steel angle iron should be utilized following these instructions. CAUTION: When using the Isokern brick ledge, it is required that the firebox/smoke dome assembly include the placement of a 4” x 4” x 3/8” minimum steel angle across the firebox opening. (See page 50 for “Structural Information”for details regarding specification and placement of steel angles in fireplaces.) This item is not included in...
  • Page 26 Earthcore Industries MAGNUM Series Fireplace Assembly Instructions - MAGNUM Series 28, 36, 42, & 48 Damper Beam: 28": Part #M68CC The steel angle sits in this notch. The four-inch leg of the FIGURE 22 36": Part #M68 steel angle is in the vertical position and is to be located in 42": Part #M69 alignment with the front of the firebox.
  • Page 27 Earthcore Industries MAGNUM Series Fireplace Assembly Instructions - MAGNUM Series 28, 36, 42, & 48 8. Set the rear smoke dome component across the FIGURE 25 damper beam in a bed of Earthcore Adhesive and flush 2 3/4” with the back face of the back damper beam lintel. Set the front smoke dome component in Earthcore Smoke Dome: Adhesive across the front damper beam and 23/4"...
  • Page 28: Dm Chimney Components & General Information

    Isokern Small Crown Cap fireplace, insulation may be installed behind sheathing of gypsum board, plywood, particle board, or other material on the side facing the Isokern. The facing material cannot be within 1½” to the fireplace side walls. Isokern Large Crown Cap...
  • Page 29: Dm Chimney Height Requirements

    Earthcore Industries MAGNUM Series Fireplace Chimney Height Requirements The DM chimney component weights are as follows: FIGURE 28 LESS THAN 10’-0” Small crown cap: 80 lb. Large crown cap: 100 lb. Brick ledge: 110 lb. 6" Inner Liner: 19 lb. 12"...
  • Page 30: Dm Chimney Installation - Straight Run

    Earthcore Industries MAGNUM Series Fireplace DM Chimney Installation - Straight Run Where the chimney run is to be straight run the DM chimney by setting FIGURE 31 a DM outer liner in a bed of Earthcore Adhesive on top of the MAGNUM top plate where the outer liner is centered from side-to-side and flush with the back of the top plate.
  • Page 31 Earthcore Industries MAGNUM Series Fireplace DM Chimney Installation - Straight Run Lateral Support for DM Chimneys Though not required, it is recommended that where the DM chimney is built up along an exterior wall the vertical FIGURE 32 chimney system can be connected to the structural wall system at a minimum of four-foot (4’) intervals.
  • Page 32: Dm Chimney Installation - Offset Run

    For vertical DM chimney to bypass overhead obstructions, the FIGURE 34 Isokern offset chimney block is used. Offset blocks are six inch (6”) thick, single module chimney components, measuring 21½” wide by 25” long. The 14" hole passes through the block at thirty (30°) degrees.
  • Page 33 The total chimney weight above the last offset block will be the total weight of the vertical chimney plus any additional allowable loads, such as the Isokern brick ledge, its related brick or stone veneers, and any crown caps, clay pots, or other masonry chimney terminations.
  • Page 34 Earthcore Industries MAGNUM Series Fireplace DM Chimney Installation - Offset Run & Brick Ledge Offsets to the Left or Right: When offsetting chimneys to the left or right of the firebox, it is not possible to build a support column directly under the third offset block.
  • Page 35 Temporarily leave out the inner liner that fits this outer casing block. Set the Isokern brick ledge onto the flat top surface of the outer casing in a full bed of Earthcore Adhesive. Be sure to align the four 2½” holes in the brick ledge with the matching holes in the outer liner block below it.
  • Page 36: Dm Brick Ledge

    Lateral Support of DM chimneys. Load Capacity for DM Brick Ledge The sources of load delivered into the Isokern brick ledge are: (1) the total physical load of brick, stone or other masonry veneer on the brick ledge, and (2) loading due to the force of wind delivered against the exposed height of the chimney mass.
  • Page 37: Dm Chimney Crown Caps

    The small crown cap is intended for use where DM chimneys are to receive thin veneers and cultured stone that do not require the installation of the Isokern brick ledge. The small crown cap is also suitable where DM chimneys are to receive a stucco finish.
  • Page 38: Dm Chimney Terminations

    FIGURE 45 ISO-Cap The ISO-Cap is a Spark Arrestor/Rain Cap designed to fit atop the Isokern DM 54 Chimney Inner Liner and is available in Stainless Steel, Black Galvanized, Copper or a Stainless Steel with Damper (Figure 45). A 14"-diameter sleeve projects from the bottom of the ISO- Cap and inserts into the DM 54 Inner Liner.
  • Page 39: Eco-Steel/Eco-Steel+ Metal Chimney Flue

    Earthcore Industries MAGNUM Series Fireplace ECO-STEEL & ECO-STEEL+ Metal Chimney Flue The MAGNUM Series Fireplaces are tested and listed FIGURE 48 for use only with Earthcore's Proprietary ECO-STEEL & ECO-STEEL+ chimney systems complying with UL103/ULC-S604 Standard. Metal Chimney Types: ECO-STEEL A lightweight venting solution created so each section connects securely together.
  • Page 40: Component List - Eco-Steel Chimney

    Earthcore Industries MAGNUM Series Fireplace Components List - ECO-STEEL+ Air Cooled & Insulated Metal Chimney Flue Air Cooled Insulated Component Part# Description Component Part# Description 13ACECO6 6" Chimney Section 13ACECOFT Tall Cone Flashing 13ACECO12 12" Chimney Section 1-6/12 and 7-12/12 roof flashing 13ACECO18 18"...
  • Page 41: Component List - Eco-Steel+ Chimney

    Earthcore Industries MAGNUM Series Fireplace Components List - ECO-STEEL+ Air Cooled Metal Chimney Flue Component Part# Description Component Part# Description ECOP13AC-O6 6" Chimney Section ECOP13AC-VC Chimney Cap ECOP13AC-12 12" Chimney Section ECOP13AC-18 18" Chimney Section ECOP13AC-36 36" Chimney Section ECOP13-IS Attic Insulation Shield ECOP13AC-KAP Anchor Plate...
  • Page 42 Earthcore Industries MAGNUM Series Fireplace Components List - ECO-STEEL+ Insulated Metal Chimney Flue Component Part# Description ECOP13IN-06 6" Insulated Chimney Section Stainless Steel ECOP13IN-06SS 6" Insulated Chimney Section Stainless Steel ECOP13IN-12 12" Insulated Chimney Section Stainless Steel ECOP13IN-12SS 12" Insulated Chimney Section Stainless Steel 18"...
  • Page 43: Eco-Steel & Eco-Steel+ General Information

    MAGNUM Series Fireplace ECO-STEEL & ECO-STEEL+ General Information The ECO-Steel Air-Cooled and Insulated Chimney is intended for use on Isokern fireplaces. Do not use with forced draft or positive-pressure appliances. The ECO-Steel Air-Cooled and Insulated chimney system is designed to extend a maximum of 60 feet vertically and with a maximum of one (2) offset (four elbows total) of up to 30°...
  • Page 44: Eco-Steel Metal Chimney Installation

    Anchor Plate chimney has a level surface on which to attach the Isowool with Damper Anchor Plate. If the top of the Isokern does not have a level surface, then it will need to be modified accordingly. NOTE: Steel angle: 4”...
  • Page 45 Earthcore Industries MAGNUM Series Fireplace ECO-STEEL Metal Chimney Installation bob to the center of the fireplace’s flue outlet and mark FIGURE 51 Chimney the center point on the ceiling. See TABLE 1 below. Storm Mark appropriate cutting lines around the center point. Collar Cut a square hole in the ceiling.
  • Page 46 Earthcore Industries MAGNUM Series Fireplace ECO-STEEL Metal Chimney Installation Band if total chimney height is greater than 50 feet, or if the fireplace manufacturer requires it. If additional support is needed, install one or more Support Bands, which will support 30 feet of chimney (Figure 53) Slide the Support Band around the chimney and align over framed opening.
  • Page 47 Earthcore Industries MAGNUM Series Fireplace ECO-STEEL Metal Chimney Installation 7. Attic Insulation Shield: The Attic Insulation Shield must be installed where the chimney passes into an attic. Its purpose is to maintain clearances from loose packed or blown insulation from the chimney. If an Attic Shield is not used the chimney needs to be enclosed within a framed enclosure.
  • Page 48: Eco-Steel Metal Chimney Installation

    Earthcore Industries MAGNUM Series Fireplace ECO-STEEL Metal Chimney Installation Screw Or Attach the elbow to the chimney pipe, support or Rivet Straps other part. Using the offset chart, add chimney FIGURE 58 To Flashing sections between elbows. A Support Band or Screw plumbers strap is required for every 4-foot interval Or Rivet...
  • Page 49: Mechanical Draft System

    Earthcore Industries MAGNUM Series Fireplace Guide for Mechanical Draft System Mechanical Draft System for Wood and Fired Fireplace Chimney with a Single Flue Application: This is the most common form of installation Junction and is used in all jurisdictions where the 2000 or later edition of the NFPA211 has not yet been adopted.
  • Page 50: Access Modification: Combustion Air Kits, Gas & Electrical Line Feed

    Gas line for gas log sets used in the Isokern firebox can be routed through the FIGURE 63 side wall, by drilling an appropriately sized hole using a masonry drill bit (Figure 62).
  • Page 51: Firebrick Installation

    Other face joint dimensions are acceptable, however smaller joints may not leave room for heat expansion of firebrick. 3. Start the firebrick at the front edge of the floor of the Isokern firebox, Fire Brick Floor proceeding inward toward the back.
  • Page 52: Flush Wall Finish Details

    Earthcore Industries MAGNUM Series Fireplace Flush Wall Finish Detail When drywall is the wall finish at the MAGNUM face and flush with the rough face of the MAGNUM firebox and damper beam, it is recommended when installing the required firebrick lining to the interior of the firebox, that the leading edge of the firebrick –...
  • Page 53: Clearance To Combustilble Trim

    Earthcore Industries MAGNUM Series Fireplace Clearance to Combustible Trim - 28, 36, 42 & 48 Models Hearth Extensions All MAGNUM 28, 36, 42, and 48 Fireplaces shall have hearth extensions of brick, concrete, stone, tile, or other code approved non-combustible material. Suitable hearth extension material for the fireplaces shall be placed on the hearth extension’s non-combustible substrate and must extend to at least twenty inches (20”) in front of the fireplace’s finished opening and must extend to at least twelve inches (12”) beyond the sides of the finished fireplace opening (Figure 68).
  • Page 54: Outdoor Application

    Specialty Applications - Outdoor Installation The Isokern fireplace can be used in an outdoor application and is considered an "Outdoor Application" if the fireplace is a freestanding unit, located a minimum of ten feet (10') away from any structure. These structures would include your house, patio cover, detached garage, or any other standing structure (Figure 70).
  • Page 55: Two-Story Stacked Installations

    Earthcore Industries MAGNUM Series Fireplace Specialty Applications - Two-Story Stacked Installations General Information FIGURE 71 To install one Fireplace and DM chimney system above one another, as in a two-story stacked installation, both the upper and lower fireplace installations require a structurally designed support down to footings designed by a structural engineer.
  • Page 56 NOTE: Widths of both Isokern Standard and MAGNUM fireplaces are the same. Only the depth of the firebox and the height of the finished opening differ.
  • Page 57: Seismic Requirements

    Specialty Applications – Reduced Height Fireplace Opening The Isokern Fireplace can have a reduced height opening by removing one layer of backwall and side walls from the fireplace construction. All other construction for the fireplace will remain the same, as shown on pages 18-28. (Figure...
  • Page 58: Summary

    2. Fireplace Curing Instructions It is critical that the Isokern masonry elements in the firebox and smoke dome assembly be dry before firing of the unit. Moisture left in the components from exposure during storage and shipping, as well as moisture from the instal- lation phase, must be eliminated before the unit is put to its intended use.
  • Page 59 6. Fireplace Doors and Screens The following door manufacturers are approved for installation and use on all Isokern gas fireplaces. We require an outside air kit be installed into the fireplace with a minimum duct size of 4” to provide adequate make up air supply.
  • Page 60 Earthcore Industries MAGNUM Series Fireplace Summary 7. Disposal of Ashes It is recommended that the firebox be cleaned of excessive ashes before each use. It is necessary to remove ashes from the open front of the fireplace. To do so, proceed in the following manner: Allow the fire to go out and the ashes to cool for at least 6 to 8 hours.
  • Page 61: Registration Card

    Earthcore Industries MAGNUM Series Fireplace Registration Card Earthcore Industries Attn: Technical Department 6899 Phillips Industrial Blvd Jacksonville, FL 32256 Dealer _______________________________________________________________________________________________ Date of Purchase: ______________________________ Date of Installation: _____________________________________ Address: _____________________________________________________________________________________________ City, State, Zip: _______________________________________________________________________________________ Phone No.: ___________________________________ MAGNUM Fireplace Size (Circle One): 28 (82028) 36 (82036) 42 (82042)
  • Page 62 Earthcore Industries MAGNUM Series Fireplace Notes _________________________________________________________________________________________________ _________________________________________________________________________________________________ _________________________________________________________________________________________________ _________________________________________________________________________________________________ _________________________________________________________________________________________________ _________________________________________________________________________________________________ _________________________________________________________________________________________________ _________________________________________________________________________________________________ _________________________________________________________________________________________________ _________________________________________________________________________________________________ _________________________________________________________________________________________________ _________________________________________________________________________________________________ _________________________________________________________________________________________________ _________________________________________________________________________________________________ _________________________________________________________________________________________________ _________________________________________________________________________________________________ _________________________________________________________________________________________________ _________________________________________________________________________________________________ _________________________________________________________________________________________________ _________________________________________________________________________________________________ _________________________________________________________________________________________________ _________________________________________________________________________________________________ _________________________________________________________________________________________________ _________________________________________________________________________________________________ _________________________________________________________________________________________________ _________________________________________________________________________________________________ _________________________________________________________________________________________________ _________________________________________________________________________________________________ _________________________________________________________________________________________________ _________________________________________________________________________________________________ _________________________________________________________________________________________________ _________________________________________________________________________________________________...
  • Page 63 Earthcore Industries MAGNUM Series Fireplace Notes _________________________________________________________________________________________________ _________________________________________________________________________________________________ _________________________________________________________________________________________________ _________________________________________________________________________________________________ _________________________________________________________________________________________________ _________________________________________________________________________________________________ _________________________________________________________________________________________________ _________________________________________________________________________________________________ _________________________________________________________________________________________________ _________________________________________________________________________________________________ _________________________________________________________________________________________________ _________________________________________________________________________________________________ _________________________________________________________________________________________________ _________________________________________________________________________________________________ _________________________________________________________________________________________________ _________________________________________________________________________________________________ _________________________________________________________________________________________________ _________________________________________________________________________________________________ _________________________________________________________________________________________________ _________________________________________________________________________________________________ _________________________________________________________________________________________________ _________________________________________________________________________________________________ _________________________________________________________________________________________________ _________________________________________________________________________________________________ _________________________________________________________________________________________________ _________________________________________________________________________________________________ _________________________________________________________________________________________________ _________________________________________________________________________________________________ _________________________________________________________________________________________________ _________________________________________________________________________________________________ _________________________________________________________________________________________________ _________________________________________________________________________________________________...
  • Page 64: Warranty

    Warranty & Disclaimer Isokern MAGNUM Series Fireplace Earthcore offers a lifetime warranty for all Isokern components, to be free from defects in materials that negatively affect system performance from the date of purchase, subject to the terms and conditions of this limited warranty.