NOTE
F1 Info
Information about the selected parameter is displayed.
Info Channel
Speed
Fuel pressure
Injection quantity
Accelerator position
2. Select and confirm > Parameters <.
Info Parameters
Accelerator position
An accelerator pedal potentiometer signals to the control unit ...
Display Explanation
% Values in per cent
NOTE
F3 Channel
Selection window with all the parameter groups.
Hella Gutmann Solutions has prepared a preliminary selection for certain diagnostic tasks.
By selecting one group, you can call up the parameters required for the diagnosis.
Group selection
All parameters
Basic function
Engine Start
xxxxxx
3. Select and confirm > Group <.
Channel selection
1
Speed
3
TV - angle
5
Air mass
6
Coolant temp.
8
Lambda vltg.
F1 Help F2 Deselect F3 Nominal values
Procedure:
1. >F2< deselects all the parameters marked *.
2. Mark parameters.
3. Deselect or select parameters with .
4. Renewed establishment of communications
NOTE
If more than eight parameters are selected, observe the info message.
Info message
- Parameters are not presented in graphic form.
- The measured values will not be stored in the diagn. folder.
B1
1/min
B2
°
B2
B3
°C
B7
mV
ESC
3