Hella Gutmann mega macs 50 User Manual

Hella Gutmann mega macs 50 User Manual

Portable diagnostic device for the identification and rectification of faults in vehicle electronic systems
Hide thumbs Also See for mega macs 50:

Advertisement

User's Manual
mega macs 50

Advertisement

Table of Contents
loading

Summary of Contents for Hella Gutmann mega macs 50

  • Page 1 User‘s Manual mega macs 50...
  • Page 2 CONTENTS Subject Section Page Device description Views 3 — 4 Keypad Changing the batteries Screen functions 6 — 7 Settings Display Company data 9 — 10 Version Update 12 — 15 Interface 16 — 20 Language Batteries System parameters Simulation Test function D10 Diagnosis folder D11 Diagnosis Control unit communications 26 — 30 Reading/deleting fault codes 31 — 32 Reading parameters 33 — 35 Actuator Service reset 37 — 38 Basic settings Coding Multimeter Settings...
  • Page 3 • Voltage, current, resistance, temperature • Two-channel multimeter Key Function Print PRINT Escape/return Function keys Cursor up/down Cursor to the right Cursor to the left ENTER key On/off switch ON/OFF mega macs 50 TFT display and keypad > Print < If mega macs 50 is connected to a PC, data can be transmitted and printed out. The >Gutmann Portal< programme must be installed on the PC (see section D4). Printing Print window The current window will be printed Diagnosis folder printer The diagnosis folder is opened, and the selected diagnosis printed. Diagnosis folder e-mail Not yet released Remote support enquiry Not yet released Start remote Linked to Gutmann >Remote< programme Send protocol data...
  • Page 4 Channel 2 Diagnostic connection ST2 for diagnostic cable and current clamp Test connection, plus Channel 1 Test connection, minus Channel 1 mega macs 50 - Bottom Connecting sockets from left to right Connections Mains Power supply unit and charger USB device PC connection for data update and communication with PC programs USB host External hardware activation Serial interface RS232 mega macs 50 - Back Extending support Rating plate mega macs 50 Section B 2/3...
  • Page 5 Changing the rechargeable batteries Procedure: 1. Switch off mega macs 50 and remove all connecting leads. 2. Remove the protective casing, starting at the narrow end. 3. Remove six fastening screws using a suitable tool, e.g. >PH1<. 4. Open up the back panel to the right. CAUTION Do not pull off any cable plugs. 5. Carefully lever off the plastic cover using a suitable tool. 6. Replace the batteries, pay attention to correct polarity. 7. R eassemble in the reverse order. NOTE Recycle used batteries in accordance with the applicable environmental and disposal regulations. mega macs 50 Section B 3/3...
  • Page 6 Selection window The selection window is highlighted in blue and displays the menu options. mega macs 50 > Diagnosis > Peugeot > 306 Diesel Header 306 1.9 D WJY (DW8) 00-01 306 1.9 D DJZ (XUD9Y) 93-00 306 2.0 D HDI RHY (DW10TD) 99-01 Selection window 306 1.9 TD DJY (XUD9A) 94-99 306 1.9 D WJZ (DW8) 98-00 F3 Search Footer Checking display Checking display functions red No connection with external systems yellow External systems connected, mega macs ready for communication. green/yellow flashing Active communication with external systems Procedure: Select and confirm line. mega macs 50 Section C 1/2...
  • Page 7 Header Speed Display window Coolant temperature °C 69.0 Brake light switch F1 Info F3 Channel Footer Footer The footer indicates the significance of the function keys. Keys F1, F2 and F3 bring up a text corresponding to the selected menu, explaining its function. Example: F1 Info, F3 Channel A selection window is opened with the F2 menu function key. Functions are called up according to the menu option. Example: F2 zero balance, zero line and trigger. mega macs 50 Section C 2/2...
  • Page 8 SETTINGS All the programs required to • adjust • check and • install updates to mega macs 50 are stored in the main > Settings < menu. Settings > Display < The brightness of the display can be adjusted in the > Display < menu. mega macs 50 > Settings Display Company data Version Update Interface Language Batteries System parameters Simulation Test function Diagn. folder Procedure: 1. Select and confirm > Display < . Brightness Brighter Darker 2. Select brighter/darker. 3. Change setting: press and hold key. 4. Return with mega macs 50 Section D1 1/1...
  • Page 9 Autohaus Autohaus Name 2 Name 2 Mustermann Mustermann Street Bergstrasse 5 POSTCODE POSTCODE 79XXX 79XXX Town Town Somewhere Somewhere 2. Select and confirm address box. Helligkeit mega macs 50 > Settings Street Bergstrasse 5 F1 Delete F3 Return Enter Enter Accept UP Keypad NOTE Hihghlighted in blue This entry is marked. Cancel the marking with key Mark with keys. Deletes the marked entry. Deletes all entries to the left of the mark. Enter Accepts all the entries in that field. Corresponds to the key. The virtual keypad is opened, marked entries are deleted. mega macs 50 Section D2 1/2...
  • Page 10 4. Open the virtual keypad. ABCDEFGHIJKLMNOPQRSTUVWXYZ a b c d e f g h i j k l m n o p q r s t u v w x y z 1234567890 . , - + / % & < > ( ) ; : _ äÄöÖüÜß Street Bergstrasse 5 Using the keypad Select character Accept character Space Underscore before the umlauts in the bottom line 4. End input. 5. Accept address box. Info message Accept settings conclusively? ENTER (Yes) ESC (No) 6. Confirm message accordingly. 7. Enter inputs into the other address boxes as described above. 8. Return to main menu with 2 x The inputs are stored and can be printed out on the diagnosis folder report. mega macs 50 Section D2 2/2...
  • Page 11 Settings > Version < All the information required to identify mega macs 50 is stored here. Helligkeit Versions Overview Program Software 1.40.xx Data version Data 32.05.xxx Design 1.4 (31.xxx) Circuit Housing Hardware 1.xx Customer assignment Device No. 12xx Production assignment Serial No. 12xx In the event of a fault, these data will be required by Hella Gutmann Solutions. CAUTION It is not possible to update mega macs 50 without the device number. mega macs 50 Section D3 1/1...
  • Page 12 Settings > Update < Hella Gutmann Solutions makes an update for mega macs 50 available to the customer twice a year. These updates are subject to a charge. They cover not only new vehicle systems, but also technical modifications and improvements. We recommend keeping your mega macs 50 up to date through regular updating. Requirements • Web compatible PC • A cleared partner licence A or B from Gutmann Messtechnik • > Gutmann Portal < programme installed on the PC • Free USB interface on the PC • Power supply from mega macs 50 via power supply unit NOTE Data transmission can be made with a USB cable or with Gutmann > air macs <. CAUTION Depending on the type of transmission, the corresponding settings must be done in mega macs 50 and in the > Gutmann Portal < programme on the PC. Steps applicable to the PC: 1. Start the internet browser on the PC. 2. Start the > Gutmann Portal < on the PC. 3. Select > Gutmann Update < in the header and confirm. CAUTION Determine the desired interface in the > Settings < menu. mega macs 50 Section D 1/...
  • Page 13 4. Select and confirm > mega macs 50 <. 5. Confirm message > Click here to ... <. The PC is set up for data transmission. mega macs 50 Section D 2/...
  • Page 14 Procedure applicable to mega macs 50 1. Connect mega macs 50 to a 220 V socket by way of the power supply unit. CAUTION During an update, mega macs 50 must be supplied with power through the power supply unit and must not be disconnected from the power source during the update. 2. Switch on mega macs 50 and call up the > Settings < > Update < menu Update Update System check 3. > Update < Helligkeit Data transfer ..., data check Action :Start with ENTER Interface :USB File name :xxxxx File size :123563 File bytes :23456 Update size :1257693576 Total files :245 Faulty files :xxx 4. Start the update. 5. > Update successfully completed < is displayed at the end of the update. Action Update successfully completed Interface File name xxxx...
  • Page 15 Fault messages after the update Procedure: 1. Select and confirm > Update < in the > Settings < menu. Update Update System check System update 2. Select and confirm > System check <. 3. The system check will be carried out automatically and the table below displayed on completion. Action Update successfully completed Interface File name xxxx File size File bytes Update size Total files Faulty files A:\DADLxx.DEF 4. Return with If the >Faulty files< entry is greater than 0, update the system with the >System update< menu. Follow the instructions on the screen. Info message System files successfully updated. On restarting, the files will be active. Return with mega macs 50 Section D /...
  • Page 16 Settings >Interface< The interfaces required for communication with a PC are determined and set in this menu. mega macs 50 > Settings Display Company data Version Update Interface Language Batteries System parameters Simulation Test function Diagn. file 1. Select and confirm > Interface <. mega macs 50 > Settings Interface RS232 Wireless 2. Select and confirm > RS232, USB or Wireless <. NOTE The fastest and most reliable interface is USB. CAUTION If RS232 is selected, the baud rate must be set. The baud rates of mega macs 50 and PC must be the same. If Wireless is selected, > air macs base < must be connected to the PC. mega macs 50 Section D5 1/5...
  • Page 17 Set RS232 baud rate Procedure: mega macs 50 > Settings > Interface Interface RS232 baud rate Wireless PC search 1. Select and confirm > RS232 baud rate <. Baud rate 9600 19200 38400 57600 115200 2. Select and confirm the baud rate. 3. Return with CAUTION The baud rates of PC and mega macs 50 must be the same. Wireless PC search NOTE The connection can be sought in this menu to verify a secure connection via Wireless. mega macs 50 Section D5 2/5...
  • Page 18 Procedure applicable to the PC 1. Connect > air macs base < to the PC. 2. Start > Gutmann Portal < on the PC. 3. Select and confirm > Settings <. 4. Select and confirm > Change <. 5. Select and confirm > Wireless <. 6. Return with mega macs 50 Section D5 3/5...
  • Page 19 Procedure applicable to mega macs 50 mega macs 50 > Settings > Interface Interface RS232 baud rate Wireless PC search 1. Select and confirm > Interface <. Interface RS232 Wireless 2. Select and confirm > Wireless <. mega macs 50 > Settings > Interface Interface RS232 baud rate Wireless PC search 3. Select and confirm > Wireless PC search <. Info message Searching for Wireless PC (takes approx. 1 minute). Please wait. mega macs 50 Section D5 /5...
  • Page 20 This message appears after a short time: Info message Wireless PC found and established as reciprocal. 4. Confirm message. The data transmission via Wireless is set up. Fault message Info message No device with Wireless found. 5. Check connection and installation of > air macs base < on the PC. Settings > Language < Selection of the desired language for mega macs 50. NOTE Multiple languages on the device are an optional feature. Appropriate information can be obtained from Gutmann Messtechnik. mega macs 50 Section D5/D 5/5...
  • Page 21 Settings > Batteries < The nominal capacity of the installed batteries is set in the > Batteries < menu. The set value affects the charging process and the display showing the state of charge of the battery. A value of 1500 mAh is set ex works. CAUTION Incorrect inputs will lead to faulty charging processes which will affect the operating reliability of mega macs 50. mega macs 50 > Settings Display Company data Version Update Interface Language Batteries System parameters Simulation Test function Diagn. folder 1. Select and confirm > Batteries <. Battery capacity (mAh) 1500 2. Put in the values via the virtual keypad (see section D2). mega macs 50 Section D7 1/1...
  • Page 22 System parameters Simulation Test function Diagn. folder 1. Select and confirm > System parameters <. Helligkeit System parameters Battery state of charge < 15%: connect charger Battery current 731.98 Pos. value = charging current, neg. value = discharge current Battery voltage 11.54 Nominal value 9 – 12 V OBD voltage 13.80 Voltage at PIN 16 of the diagnostic plug Power supply unit voltage 15.32 Charging voltage of power supply unit UPOW voltage 14.53 Auxiliary voltage for communication Voltage + 17 V 16.90 Auxiliary voltage for communication Voltage + 3.3 V 3.38 Supply voltage for electronics ST2 voltage 2.37 Internal auxiliary voltage 2. Return with mega macs 50 Section D 1/1...
  • Page 23 Settings > Simulation < A program can be called up in the > Simulation < menu, with which the user can practise the use of mega macs 50. The simulation facility applies to the use of > Reading/deleting fault codes < and > Parameters <. CAUTION If a vehicle is connected when the simulation function is active, no communication will be established with the selected system. The displayed values will be incorrect. The simulation function will no longer be active when mega macs 50 is started next time. mega macs 50 > Settings Display Company data Version Update Interface Language Batteries System parameters Simulation Test function Diagn. folder 1. Select and confirm > Simulation <. Simulation 2. Select and confirm function. Info message Accept setting conclusively? ENTER (Yes) ESC (No) 3. Confirm the message accordingly. mega macs 50 Section D 1/1...
  • Page 24 Display Company data Version Update Interface Language Batteries System parameters Simulation Test function Diagn. folder Procedure: Connect the power supply unit to mega macs 50. 1. Select and confirm > Test function <. 2. Connect ST2 cable to mega macs 50. 3. Continue with The following messages may be displayed: Info message A fault has occurred Line: Range: Number: Nominal level Actual level The diagnostic plug, connecting cable or mega macs 50 is defective, Info message Test successfully completed mega macs 50 is OK.
  • Page 25 Settings > Diagn. folder < The settings with which the diagnosis folder can be configured are stored in the > Diagn. folder < menu. mega macs 50 > Settings Display Company data Version Update Interface Language Batteries System parameters Simulation Test function Diagn. folder 1. Select and confirm > Diagn. folder <. Diagnosis folder settings Print out company data as well: Database connection Local 2. Select and confirm box. 3. Select and confirm setting. 4. Return with mega macs 50 Section D11 1/1...
  • Page 26 • Carrying out coding of control units • Carrying out service reset CAUTION Faultless communication is possible only when: · all the pins are correctly assigned at the diagnostic socket · the vehicle has been correctly identified · Identify the vehicle as precisely as possible by reference to the search mask · the voltage of the vehicle‘s electrical system is not lower than 11.5 V; if necessary, use external power supply · all power consumers are off · the diagnostic plug is connected to the vehicle · external accessories, radio, CD changer etc. are correctly connected · the ignition is turned on NOTE Always turn off the ignition before connecting or disconnecting the diagnostic plug to/from the vehicle! If you wish to read out several fault memories one after the other one vehicle, turn off ignition after every readout procedure and turn on again for the next procedure. Procedure: 1.Switch on mega macs 50 with ON/OFF mega macs 50 Diagnosis Multimeter Diagn. folder Settings mega macs 50 Section E 1/5...
  • Page 27 2. Select and confirm > Diagnosis <. mega macs 50 > Diagnosis Alfa Audi Chrysler Citroen Daewoo …….. …….. ……. Peugeot 3. Select and confirm > Manufacturer <. mega macs 50 > Diagnosis > Peugeot Petrol Diesel 4. Select and confirm > Fuel <. mega macs 50 > Diagnosis > Peugeot F1 Put in licence plate number. NOTE Put in licence plate number. To identify the vehicle in the diagnosis folder, put in the licence plate number via the virtual keypad (see section D2). 5. Select and confirm > Vehicle Group <. mega macs 50 Section E 2/5...
  • Page 28 Model 306 2.0 D HDI Engine code RHY (DW10TD) Model year 99-01 Rated output 66 kW Displacement 1997 cc Type key number Gutmann number F3 search NOTE A bright information window will appear for about 15 seconds giving data relating to the marked vehicle. F3 Search opens a window with search criteria by which the vehicle can be identified. Press >F3<. Model Engine code Model year Rated output Type key number Diagn. programme NOTE Re: > Type key number < The first three digits in box 2.2 of the vehicle registration document, part 2 (for Germany only). NOTE Re: > Diagnostic programme < Possible types of diagnosis for the selected vehicle are displayed. 6. Search criterion, in this case engine code Header 7. Select and confirm the engine code. mega macs 50 Section E 3/5...
  • Page 29 NOTE F1 Info Information about the selected system. F2 Menu Information about communication parameters. In the event of a complaint, Hella Gutmann Solutions uses this information for fault identification and rectification. Leave information with ESC. CAUTION Changes to the data can lead to malfunctions. 14. Continue with mega macs 50 Section E /5...
  • Page 30 CAUTION Follow the instructions on the screen without fail. 15. Continue with > Fault code > Engine > Init vehicle ********* Lucas DCN2 Communication with the control unit is established. For further information, refer to the sections on types of diagnosis. mega macs 50 Section E 5/5...
  • Page 31 1. Connect mega macs 50 as described in section E to establish communication.. > 306 > 306 2.0TD HDI > Fault code > Engine Number of faults: 3 Fault code: 832 CAMSHAFT SENSOR Fault code: 560 PRIMARY CIRCUIT, FUEL PUMP Fault code: 545 ACCELERATOR PEDAL SENSOR 2 F1 System info F3 Delete ENTER Details 2. Select and confirm > Fault code <. NOTE F1 System info Information on the installed system if supported by the manufacturer. Delete F3 All displayed fault codes will be deleted. ENTER details Information about the marked fault will be displayed. > 306 > 306 2.0TD HDI > Fault code > Engine Fault code 832 FAULTY CAMSHAFT SENSOR FAULTY SIGNAL FUNCTION: The sensor detects the camshaft position; the ignition and injection systems are synchronised and/or the position of the variable camshaft control detected via the signal. EFFECT: Poor starting behaviour, etc. CAUSE: >>> Circuit interruption/short circuit F3 Delete fault F3 Menu All the information can be displayed by scrolling. mega macs 50 Section F 1/2...
  • Page 32 Connection to the multimeter Example: >>> Circuit interruption/short circuit 1. Select and confirm. Voltage Resistance Current Voltage/Voltage Voltage/Current Temperature Comp. measurement For instructions on using the multimeter, see section M. 2. Return to the desired menu option with mega macs 50 Section F 2/2...
  • Page 33 Diagnosis > Parameters < Since the causes of faults can be interpreted differently by the control unit, it is often not sufficient to read out only the fault memory. In many cases, either fault codes are not entered or it is not possible to obtain an unequivocal statement about the defective component from the fault text. Example 1: The engine temperature may vary within a range of -30°C to +120°C. If the sensor signals +9.0°C, although the actual temperature in the engine is +80°C, the control unit will determine an incorrect injection time. No fault code will be set, as this temperature is logical for the control unit. Example 2 Fault text: Lambda probe signal faulty In both cases, a diagnosis can only be carried out if the corresponding parameters are read out. mega mac 50 reads the parameters out and presents them in plain text. If up to 4 parameters are selected, they will also be displayed in graphic form. A maximum of 8 parameters can be called up, but in this case they will not be presented in graphic form. A task-orientated selection of the parameters facilitates fault diagnosis. Information on the parameters is stored. Procedure 1. Connect mega macs 50 to establish communication as described in section E. > Parameters > Engine Speed 1/min Fuel pressure Injection volume mm_/H 11.7 Accelerator position F1 Info F3 Channel mega macs 50 Section G 1/3...
  • Page 34 % Values in per cent NOTE F3 Channel Selection window with all the parameter groups. Hella Gutmann Solutions has prepared a preliminary selection for certain diagnostic tasks. By selecting one group, you can call up the parameters required for the diagnosis. Group selection All parameters Basic function Engine Start xxxxxx 3. Select and confirm > Group <. Channel selection Speed 1/min TV - angle ° Air mass Coolant temp. °C 8 Lambda vltg. F1 Help F2 Deselect F3 Nominal values Procedure: 1. >F2< deselects all the parameters marked *. 2. Mark parameters. 3. Deselect or select parameters with . 4. Renewed establishment of communications NOTE If more than eight parameters are selected, observe the info message. Info message - Parameters are not presented in graphic form. - The measured values will not be stored in the diagn. folder. mega macs 50 Section G 2/3...
  • Page 35 NOTE F3 Nominal values Nominal values for the parameters can be called up depending on manufacturer. Channel selection Speed O2 Integrator ° Air flow meter Coolant temp. °C 8 Lambda vltg. F1 Help F2 Deselect F3 Nominal values Procedure: 1. Mark parameter, in this case speed. 2. Press >F3<. Speed Vehicle-specific data Engine at operating temperature, idling 710 - 890 1/min Possible faults: - Idle actuator or TV actuator faulty - xxxxxx 3. Return with mega macs 50 Section G 3/3...
  • Page 36 Diagnosis > Actuator < Components in electronic systems are activated with the > Actuator < menu. Therefore it is possible to check the basic functions and cable connections of these components. DANGER To prevent damage to the system, the instructions shown on the screen must be followed without fail. Establish identification and communications as described in section E NOTE The course of the actuator test is automated by many manufacturers and is determined by the control unit. mega macs 50 Section H 1/1...
  • Page 37 Diagnosis > Service reset < Depending on the make of vehicle, the service intervals are reset in the > Service reset < menu. Either a description is given as to how the manual reset is to be carried out, or the automatic reset is carried out by mega macs 50. The identification and the establishment of communications correspond to section E. Manual reset …geot > Diesel > 306 > 306 2.0D HDI/RHY (DW10TD) Fault code Parameters Service reset Basic setting Coding 1. Select and confirm > Service reset <. Helligkeit …geot > Diesel > 306 > 306 2.0D HDI/ RHY (DW10TD) Manual reset Resetting the Peugeot service interval display. Procedure: 1. Ignition OFF 2. Press and hold the reset button between the fuel level display and tachometer and turn on the ignition; the key symbol will light up. 3. A countdown of 10 seconds appears in the display. Keep the button depressed during these 10 seconds. 2. Further information can be obtained by scrolling mega macs 50 Section J 1/2...
  • Page 38 Automatic reset The identification and establishment of communication corresponds to section E. … > Diagnosis > Volkswagen > Benzin > Golf42.0i/AQY Resetting service interval Oil change Inspection 1 Inspection 2 F3 Reset 1. Select and confirm interval. 2. Press F3. 3. The resetting process will be carried out after communications have been established. CAUTION Follow the instructions on the screen without fail. mega macs 50 Section J 2/2...
  • Page 39 Diagnosis > Basic settings < The data relating to components which, e.g. have been replaced, are adjusted or adapted in accordance with the manufacturer‘s specification in the > Basic settings < menu. The identification of the vehicle and establishment of communication correspond to section E. CAUTION Clear the fault memory before carrying out any basic settings. Ensure certain conditions (depending on the manufacturer) in order to carry out the basic setting. Observe the instructions in mega macs 50 without fail. DANGER Incorrect basic settings can lead to major malfunctions. Procedure: > BMW > Diesel > 530 (E60) > M57 D30 Venting fuel system Initialising steering angle sensor Adjusting xenon light 1. Select and confirm > System <. 2. Follow the instructions on the screen. mega macs 50 Section K 1/1...
  • Page 40 Diagnosis > Coding < The coding of control units and components is carried out in the > Coding < menu. Codings are required when components were replaced or if additional functions must be activated in an electronic system. The vehicle identification and the establishment of communication correspond to section E. Procedure > BMW > Diesel > 530 (E60) > M57 D30 Engine control units CAN gateway Automatic air conditioning Transport mode F1 Help NOTE F1 Information on the system and help in carrying out the coding Helligkeit Help message In the transport mode, the control units go into an inactive mode in order to save the battery. The vehicle is released for normal on-road use by the coding. 1. Select and confirm > System <. 2. Follow the instructions on the screen without fail. mega macs 50 Section L 1/1...
  • Page 41 MULTIMETER The purpose of mega macs 50 multimeter is to measure voltage, resistance, current and temperatures of vehicle components. The measuring parameters for various components are preset in the > Comp. measurement < menu. Measuring ranges Voltage/time: 0 — 200 V 0 s — 100 s Resistance/time: 0 — 1000 kOhm 0 s — 100 s Current/time: 0 — 400 A 0 s — 100 s Temperature: - 30 — + 550 °C CAUTION Reset the measured value with F1 before every measurement. The current clamps take account of the technical current direction and are therefore marked with an arrow which must be aligned in accordance with the intended task. DANGER Testing and safety regulations must be observed when carrying out any measurements. Carry out resistance measurements only on de-energised components. mega macs 50 > Multimeter Voltage Resistance Current Voltage/Voltage Voltage/Current Temperature Comp. measurement 1. Select and confirm > Measuring mode <. mega macs 50 Section M 1/10...
  • Page 42 General settings mega macs 50 > Multimeter 0 — 20 Measuring axis V, A, Measuring unit Ohms, °C 13.0 13.0 Measured value AC/DC Type of voltage 0 — 10 Time axis ENTER Start/Stop F1 Zero reset F2 Menu CAUTION Use the green/black connecting socket. Change the measuring axis with Change the time axis with NOTE ENTER Start/Stop The current display will be saved — snapshot function. To continue measurement, press ENTER again. F1 Zero reset The measured value will be reset. F2 Menu Setting of zero line, trigger level, trigger setting and type of voltage. The setting functions will be shown in the footer. mega macs 50 Section M 2/10...
  • Page 43 Settings under F2 Zero line Zero line AC/DC Start/Stop Zero reset 1. Select and confirm > Zero line <. mega macs 50 >Multimeter > Voltage 13.0 UP zero line + DOWN zero line - Raise zero line. Lower zero line. NOTE If no cursor key is pressed within 5 seconds, the setting function will be discontinued and the standard display in the footer will be called up. mega macs 50 Section M 3/10...
  • Page 44 If AC is selected, only the AC voltage values of a signal will be displayed, e.g. the harmonics of the generator. If DC is selected, all the voltage values of a signal are displayed, e.g. battery, throttle valve potentiometer etc. Connection Channel 1. DC 2. Confirm > Channel 1: xx <. Connection 3. Select and confirm > AC <. Connection Channel 1. AC Return with mega macs 50 > Multimeter > Voltage 13.0 - 0. 1 - 0. 2 - 0. 3 ENTER Start/Stop F1 Zero reset F2 Menu NOTE Set the measuring range and zero line according to the signal. mega macs 50 Section M /10...
  • Page 45 Trigger NOTE If the time axis is set at less than 1.0 s, the trigger can be selected. A trigger is required to display a voltage curve. The trigger releases a new image as soon as the signal reaches a defined voltage. After startup, mega macs 50 is always set to automatic triggering. In order to stabilise high-speed signals, it is often necessary to change the trigger point. The required settings can be accessed under F2. Zero line AC/DC Start/stop Zero reset 1. Select and confirm > Trigger <. Trigger edge NOTE > Positive edge < Trigger orientation towards rising voltages. > Negative edge < Trigger orientation towards falling voltages. Any change in the edge will displace the image towards the right or left. Trigger settings Edge: Positive Mode: Auto 2. Select and confirm > Edge xx <. Trigger edge positive negative 3. Select and confirm > positive < or > negative <. Accept setting with mega macs 50 Section M 5/10...
  • Page 46 Trigger mode NOTE mega macs 50 is set to automatic triggering after startup. If the presentation of a signal is unclear or is particularly irregular, mega macs 50 can be set to manual triggering. Trigger settings Edge: positive Mode: Auto 1. Select and confirm > Mode xx <. Trigger mode Auto Manual 2. Select and confirm > Auto < or > manual <. 3. Accept setting with mega macs 50 Section M /10...
  • Page 47 Trigger level NOTE In the > Manual < trigger mode, the trigger level can be shifted in order to achieve the optimum stabilisation of a signal curve. Zero line Trigger level Trigger AC/DC Start/stop Zero reset 1. Select and confirm > Trigger level <. mega macs 50 > Multimeter > Voltage 13.0 Trigger + UP Trigger level + DOWN Trigger level - The trigger level is represented by a red cross. Raise trigger level. Lower trigger level. CAUTION After leaving the program, the device is reset to the standard settings. mega macs 50 Section M 7/10...
  • Page 48 Two-channel multimeter The two-channel multimeter permits comparative measurements of components. The settings and operation are as described previously. mega macs 50 > Multimeter > Voltage/Current 10.0 ENTER Start/Stop F1 Zero reset F2 Menu F3 Active channel CAUTION 48 Use the red/black connecting socket. NOTE F3 Active channel Black bars on the right and left indicate the active channel. Settings can only be made here. For the procedure, see above. mega macs 50 Section M /10...
  • Page 49 Exhaust system Manifold Mixture/misfire Catalyst Effect Air conditioning Condenser Flow rate Air conditioning, autom. Sensors NOMINAL/ACTUAL Heating Heat exchanger Flow rate Rear window Heating Wires Drive train Bearings/bushes Wear Brakes Discs/drums Effect Tyres Tread Steering geometry setting 80 CAUTION Before it is used for the first time, mega macs 50 must be calibrated to the IR thermometer. Calibration mega macs 50 > Multimeter > Temperature measurement °C ENTER Start/Stop F2 Menu 1. Press >F2< . mega macs 50 Section M /10...
  • Page 50 Zero line Temperature reset Start/Stop 2. Select >Temperature reset< and confirm. 3. Follow the instructions on the screen. Info message Reset low temperature NOTE Temperatures are put in using the virtual keypad. Component measurement In order to simplify the measuring process for inexperienced users, the measuring ranges of mega macs 50 are preset to the values required for the component in the > Comp. measurement < menu. 1. Select and confirm > Comp. measurement <. 2. Select and confirm > Component <. Multimeter > Comp. measurement < Lambda probe 1 V ENTER Start/stop F2 Menu CAUTION 50 Use the green/black connecting sockets for mega macs 50. mega macs 50 Section M 10/10...
  • Page 51 Vehicles stored in this way can be called up in the > Diagn. folder < menu. The data can be displayed directly on mega macs 50 or printed out by way of a PC with the > Gutmann Portal < programme. Printing diagnosis folder Steps: mega macs 50 Diagnosis Multimeter Diagn. folder Settings 1. Select and confirm > Diagn. folder <. mega macs 50 Diagnosis folder selection 0004 BMW FR-Mxxx 0003 Fiat HH-H2xx 0002 Audi None 0001 Peugeot LU-DExx NOTE F1 Delete The selected entry will be deleted. F1 Delete 2. Select and confirm vehicle. mega macs 50 Section N 1/2...
  • Page 52 1002.3i AAR Fault code Engine Fault code Fault code Engine PRINT Print F3 Load NOTE PRINT All the data will be printed out (see section B, page 1). F3 Load Presentation of marked entries on mega macs 50 3. Select and confirm > Type of diagnosis < (in this case fault code). NOTE Multiple markings are possible and will be printed out accordingly. 4. Press > Print <; the marked entries will be printed. 5. Return with Presentation of entries Diagnosis file selection Audi GG-D3xx 100 1002.3i AAR Fault code Engine Fault code Parameters Engine 1. Select >Type of diagnosis< (in this case, parameters). 2. Press >F3<. The marked entries will be displayed. NOTE The display can be scrolled with the or . mega macs 50 Section N 2/2...
  • Page 53 Furthermore pay attention to all instructions made by labour inspectorates, trade associations, vehicle manufacturers as well as all laws, legal ordinances and instructions, which have to be commonly obeyed by a workshop. The following is only an extract which is not intended to limit any other precautionary measures. Data protection The data, scanning software and manual are protected by copyright. In the relationship between Gutmann and the user, all the rights thereto are owned exclusively by Hella Gutmann Solutions. Any duplication of the stored data whatsoever, particularly the copying of data onto electromagnetic, optoelectronic or other data media, together with the manual, is prohibited. The user may only duplicate the program supplied if this is necessary for the purpose of using of the program. No retranslation of the programme code supplied into other types of code (decompilation) or any other method of re-acquiring the various production stages for the software (reverse engineering) is permitted. Removal of copy protection is forbidden. Data and software/program must not be transferred to a third party mega macs 50 Section O 1/...
  • Page 54 Gutmann Solutions. Hella Gutmann Solutions is not liable to pay damages arising by reason of any inability to use the objects of the contract, even if Hella Gutmann Solutions was notified of the possibility of damage of this nature. The liability of Hella Gutmann Solutions is limited to the amount actually paid for the product.
  • Page 55 Safety precautions regarding the risk of injury: When the engine is running, injuries may arise from rotating parts (fan blades, belt drives, etc.). If the vehicle is not prevented from rolling away, you could be trapped by it. • Keep the hands well clear of rotating parts when the engine is running. • Prevent the car from rolling away unintentionally (handbrake). • In the case of automatic vehicles, also set the selector lever to P position. • Do no lay connecting leads near rotating parts. Safety precautions regarding noise: To prevent hearing defects, take the following measures: • Protect workstations in the vicinity of the testing stations against noise. • Use noise insulation equipment. Safety precautions: Caustic injuries: If the LCD display is damaged, the risk of caustic injuries will arise through the escape of crystal fluid. Wash any parts of the body or clothing immediately with water (consult a doctor). • Consult a doctor immediately if the fluid has been inhaled or swallowed. mega macs 50 Section O 3/...
  • Page 56 Protect the device from hard knocks (do not allow it to fall). • Only a technician authorised by Hella Gutmann Solutions is allowed to open the device. • If the protective seal is broken or the instrument is subject to impermissible interventions, the guarantee will be invalidated.

Table of Contents