Settings >System parameters<
Voltage- and current data are stored in the > System parameters < menu which are required for the reliable
operation of mega macs 50. In the event of a fault, a corresponding diagnosis of the possible fault can be obtained
relating to these values.
mega macs 50 > Settings
Display
Company data
Version
Update
Interface
Language
Batteries
System parameters
Simulation
Test function
Diagn. folder
1. Select and confirm > System parameters <.
System parameters
Helligkeit
Battery state of charge
Battery current
Battery voltage
OBD voltage
Power supply unit voltage 15.32
UPOW voltage
Voltage + 17 V
Voltage + 3.3 V
ST2 voltage
2. Return with
ESC
45
%
< 15%: connect charger
731.98
mA
Pos. value = charging current, neg. value = discharge current
11.54
V
Nominal value 9 – 12 V
13.80
V
Voltage at PIN 16 of the diagnostic plug
V
Charging voltage of power supply unit
14.53
V
Auxiliary voltage for communication
16.90
V
Auxiliary voltage for communication
3.38
V
Supply voltage for electronics
2.37
V
Internal auxiliary voltage
22
mega macs 50 Section D 1/1