Manhattan 178495 Programming Manual

Manhattan 178495 Programming Manual

Wireless linear ccd

Advertisement

Wireless Linear CCD
Barcode Scanner
Programming Guide
Model 178495
manhattanproducts.com
MH-178495_UM-0418_REV-5.01

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 178495 and is the answer not in the manual?

Questions and answers

Summary of Contents for Manhattan 178495

  • Page 1 Wireless Linear CCD Barcode Scanner Programming Guide Model 178495 manhattanproducts.com MH-178495_UM-0418_REV-5.01...
  • Page 2 Doing so will void the Manhattan product warranty. All pictures in this manual are for reference only. The actual product may differ. Manhattan reserves the right to make changes to any software or hardware to improve reliability, function, or design at any time without notice.
  • Page 3: Table Of Contents

    User Manual TABLE OF CONTENTS Chapter 1: Getting Started ............ 4 Barcode Overview and Scanning Procedure ......4 Scanner Parameters ..............4 Chapter 2: Scanner Configuration Overview ......5 Flow Chart and Instructions............5 Factory Defaults & Custom Settings ........5 Chapter 3: Getting Connected ..........
  • Page 4: Chapter 1: Getting Started

    Wireless Linear CCD Barcode Scanner Chapter 1: Getting Started The Manhattan Wireless Linear CCD Barcode Scanner is an advanced and versatile decoding tool for barcoding systems. It works with a variety of bar code types, reading devices, and computer interfaces. In its default state, it can discern about 20 different symbologies.
  • Page 5: Chapter 2: Scanner Configuration Overview

    User Manual User Environment Environment Value Operating Temperature 0 to 50°C (32 – 122°F) Storage Temperature -20 to 60°C (-4 – 140°F) Relative Humidity 20% to 95% (non-condensing) Chapter 2: Scanner Configuration Overview Flow Chart and Instructions 1. Scan the Start Configuration barcode. 2.
  • Page 6: Chapter 3: Getting Connected

    Wireless Linear CCD Barcode Scanner Chapter 3: Getting Connected The cradle acts both as a charger for the scanner and, if programmed to do so, can be a direct link to report the data from scanned barcodes. To charge the scanner, place it on the cradle. Before First Use: •...
  • Page 7: Pair The Scanner To Another Device

    User Manual Start Configuration SPP Master Mode End Configuration Note • To pair another scanner to the cradle, use that scanner to scan the MAC Address Barcode on the cradle. The first scanner’s connection will be interrupted, and the second scanner should connect.
  • Page 8: Chapter 4: Scanner Configuration

    Wireless Linear CCD Barcode Scanner Chapter 4: Scanner Configuration Main Settings With the basics of the flow chart from chapter 2 in mind, use the following codes to configure the scanner. Save Parameters The parameter settings will be saved permanently. %$ + / 0 Recall Stored Parameters Replace the current parameters by the parameters you saved...
  • Page 9: Chapter 5: Interface And Data Retention

    User Manual Chapter 5: Interface and Data Retention Interface Selection Keyboard Mode RS232 Mode % 00 U0 WAND Emulation % 00 U8 OCIA Mode % 00 M 2 <USB Mode> % 00 M 4 % 0X O 8 Inventory Function This function allows the scanner to retain barcode data in the scanner’s memory for uploading at a convenient time.
  • Page 10: Reading Selection Mode

    Wireless Linear CCD Barcode Scanner Reading Selection Mode <Good Read OFF> % 02 71 Trigger ON/OFF % 02 70 Continuous/Trigger OFF % 02 72 Testing Continuous/Auto Power On % 02 75 %02 73 Flash Flash/Auto Power On % 02 74 % 02 76 Reserved 1 Reserved 2...
  • Page 11: Chapter 6: Communication Parameters

    User Manual Chapter 6: Communication Parameters Serial Mode Parameters Set up Baud Rate 1200 %0Y70 %0Y71 2400 4800 %0Y72 <9600> %0Y73 19200 %0Y77 38400 %0Y74 %0Y75 Set up Data Bits 7 Data Bits <8 Data Bits> %0Y80 %0Y88 Set up Stop Bits <1 Bit>...
  • Page 12 Wireless Linear CCD Barcode Scanner Set Up Parity <None> Even %0YN7 %0YN2 %0YN3 Mark Space %0YN1 %0YN0 Handshaking RTS/CTS Enable %018 8 <RTS/CTS Disable> ACK/NAK Enable %018 0 %014 4 <ACK/NAK Disable> XON/XOFF Enable %014 0 %03K 4 <XON/OFF Disable> %03K 0...
  • Page 13: Keyboard Wedge Mode Parameters

    User Manual Keyboard Wedge Mode Parameters Terminal Type <IBM PC/AT, PS/2> IBM PC/XT %0ZF0 %0ZF1 IBM PS/2 25, 30 NEC 9800 %0ZF2 %0ZF3 Apple Desktop Bus (ADB) IBM 5500 %0ZF4 %0ZF5 IBM 122 Key (1) IBM 102 Key %0ZF6 %0ZF7 IBM 122 Key (2) Reserved 1 %0ZF8...
  • Page 14 Wireless Linear CCD Barcode Scanner Upper/Lower Case <No Change> %0330 Upper Case %0331 Lower Case %0332 Send Character by ALT Method Enable %03O8 <Disable> %03O0 Select Numerical Pad %01K4 <OFF> %01K0 Capslock Detection Enable <Disable>...
  • Page 15: Output Characters Parameters

    User Manual Output Characters Parameters Select Terminator <CR + LF> %7S2+ None %7S7+ %7S0+ Space %7S1+ %7S4+ HT (TAB) STX-ETX %7S3+ %7S5+ Time-out Between Characters <0 ms> %0070 5 ms 10 ms %0071 %0072 25 ms %0073...
  • Page 16: Wand Emulation Mode Parameters

    Wireless Linear CCD Barcode Scanner 50 ms 100 ms %0074 200 ms %0075 300 ms %0076 %0077 Wand Emulation Mode Parameters TTL Level Representation <Bar Equals High> Bar Equals Low %02K4 %02K0 Scan Speed Selection <Fast> Slow %0288 %0280 Output Format Selection <Output as Code 39>...
  • Page 17: Chapter 7: Barcode Types

    User Manual Chapter 7: Barcode Types Symbologies Selection UPC-A <ON> %0074 UPC-E <ON> %0A40 %0BO8 EAN-13/JAN-13(ISBN13) <ON> %0BO0 %0A22 EAN-8/JAN-8 <ON> %0A20 %0A11 CODE 39 <ON> %0A10 %0EO8 CODE 128 <ON> %0EO0 %0FO8 CODABAR/NW7 <ON> %0FO0 %0JO8 %0JO0...
  • Page 18 Wireless Linear CCD Barcode Scanner Interleave 25 <ON> <OFF> %0GO8 %0GO0 Industrial 25 ON <OFF> %0HO8 Matrix 25 ON %0HO0 <OFF> %0IO8 CODE 93 ON %0IO0 <OFF> %0KO8 CODE 11 ON %0KO0 <OFF> %0LO8 China Postage ON %0LO0 <OFF> %0MO8 MSI/PLESSEY ON %0MO0 <OFF>...
  • Page 19 User Manual CODE 93 ON %0PO8 <OFF> %0PO0 Telepen ON <OFF> %0TO8 %0TO0 Reserved4 ON %0QO8 <OFF> %0QO0 Reserved5 ON %0RO8 <OFF> %0RO0 Reserved6 ON %0SO8 <OFF> %0SO0 LDC25 ON %0QO8 <OFF> %0QO0...
  • Page 20: Upc/Ean/Jan Parameters

    Wireless Linear CCD Barcode Scanner RSS-14 ON RSS-14 OFF %0UO8 RSS Limit ON %0UO0 RSS Limit OFF %0VO8 RSS Expanded ON %0VO0 RSS Expanded OFF %0WO8 %0WO0 Select All Bar Codes %1A/ + UPC/EAN/Jan Parameters Reading Type UPCA=EAN13 ON UPCA=EAN13 <OFF> %0AK4 ISBN-10 Enable %0AK0...
  • Page 21 User Manual ISSN Enable ISSN <Disable> %0B44 %0B40 Decode with Supplement <Autodiscriminate Supplement %01O0 %01O8 UPC-E Enable UPC-E Disable %0BH1 %0BH0 EAN8 —>EAN13 Enable EAN8 —>EAN13 Disable %0A08 GTIN Format Enable %0AO0 %0X44 GTIN Format Disable %0X40 Supplemental Set Up <No Transmission>...
  • Page 22 Wireless Linear CCD Barcode Scanner Transmit 5 Code %0B32 Transmit 2&5 Code UPC-A Check Digit %0B30 Transmission <ON> %0A12 UPC-E Check Digit %0A10 Transmission <ON> %0B12 EAN-8 Check Digit %0B10 Transmission <ON> %0A88 EAN-13 Check Digit %0A80 Transmission <ON> %0AH1 ISSN Check Digit %0AH0 Transmission <ON>...
  • Page 23: Code 39 Parameters

    User Manual Code 39 Parameters Supplemental Set Up <Standard> Full ASCII %0EH1 Italian Pharmacy/Code 32 <OFF> %0EH0 Italian Pharmacy/ Code 32 <OFF> %0E80 %0E88 Check-Digit Transmission <Do Not Calculate Check Digit> Calculate Check Digit & Transmit %0EM2 Calculate Check Digit %0EM6 but Do Not Transmit %0EM4...
  • Page 24: Code 128 Parameters

    Wireless Linear CCD Barcode Scanner Set Up Code Length Follow the steps below to set a fixed length: 1. Scan the barcode containing “Begin” for the desired set. 2. Refer to the Decimal Value Tables in Appendix A. Scan the label(s) that represent the length to be read. 3.
  • Page 25 User Manual Check-Digit Transmission Do Not Calculate Check Digit Calculate Check Digit & Transmit %0FN1 %0FN7 <Calculate Check Digit but Do Not Transmit> %0FN5 Append FNC2 %0F88 <OFF> %0F80 Set Up Code Length Follow the steps below to set a fixed length: 1.
  • Page 26: Interleave 25 Parameters

    Wireless Linear CCD Barcode Scanner 1. Begin 2nd Set 2. Scan Decimal Value (Appendix A) 3. Complete 2nd Set %4F00 %4F02 Minimum Length 1. Begin 2. Scan Decimal Value (Appendix A) 3. Complete %2+-/ %2C1+ Interleave 25 Parameters Check-Digit Transmission <Do Not Calculate Check Digit>...
  • Page 27: Industrial Parameters

    User Manual Set Up Code Length Follow the steps below to set a fixed length: 1. Scan the barcode containing “Begin” for the desired set. 2. Refer to the Decimal Value Tables in Appendix A. Scan the label(s) that represent the length to be read. 3.
  • Page 28 Wireless Linear CCD Barcode Scanner Check-Digit Transmission <Do Not Calculate Check Digit> Calculate Check Digit %0HN3 & Transmit <Calculate Check Digit but Do Not Transmit> %0HN7 %0HN5 Set Up Code Length Follow the steps below to set a fixed length: 1.
  • Page 29: Matrix 25 Parameters

    User Manual Matrix 25 Parameters Check Digit Transmission <Do Not Calculate Check Digit> Calculate Check Digit & Transmit %01N3 <Calculate Check Digit but Do Not Transmit> %01N7 %01N5 Set Up Code Length Follow the steps below to set a fixed length: 1.
  • Page 30: Codabar/Nw7 Parameters

    Wireless Linear CCD Barcode Scanner Codabar/NW7 Parameters Set Up Start/Stop upon Transmission <OFF> Transmission Type of Start/Stop <A/B/C/D><Start> <A/B/C/D><Stop> A Start A Stop B Start B Stop C Start C Stop D Start D Stop...
  • Page 31: Code 93 Parameters

    User Manual Set Up Code Length Follow the steps below to set a fixed length: 1. Scan the barcode containing “Begin” for the desired set. 2. Refer to the Decimal Value Tables in Appendix A. Scan the label(s) that represent the length to be read. 3.
  • Page 32: Code 11 Parameters

    Wireless Linear CCD Barcode Scanner Set Up Code Length Follow the steps below to set a fixed length: 1. Scan the barcode containing “Begin” for the desired set. 2. Refer to the Decimal Value Tables in Appendix A. Scan the label(s) that represent the length to be read. 3.
  • Page 33 User Manual Calculate Check 1 Digit but Do Not Transmit> Calculate Check 2 Digits and Transmit %0LN5 Calculate Check 2 Digits but Do Not Transmit %0LN6 %0LN4 Set Up Code Length Follow the steps below to set a fixed length: 1.
  • Page 34: Msi / Plessey Code Parameters

    Wireless Linear CCD Barcode Scanner MSI / Plessey Code Parameters Check Digit Transmission <Do Not Calculate Check Digit> Calculate Check Digit & Transmit %0NN3 Calculate Check Digit but Do Not Transmit %0NN7 %0NN5 Set Up Code Length Follow the steps below to set a fixed length: 1.
  • Page 35: Code 2 Of 6 Parameters

    User Manual Code 2 of 6 Parameters Check Digit Transmission <Do Not Calculate Check Digit> Calculate Check Digit & Transmit %0PN3 Calculate Check Digit but Do Not Transmit %0PN7 %0PN5 Set Up Code Length Follow the steps below to set a fixed length: 1.
  • Page 36: Telepen Parameters

    Wireless Linear CCD Barcode Scanner Telepen Parameters Type of Code <Telepen ASCII> Telepen Numeric %0PN3 %0188 Check Digit Transmission Do Not Calculate Check Digit Calculate Check Digit & Transmit %0PN3 <Calculate Check Digit but Do Not Transmit> %0PN7 %0PN5 Set Up Code Length Follow the steps below to set a fixed length: 1.
  • Page 37: Gs1 Data Bar

    User Manual Minimum Length 1. Begin 2. Scan Decimal Value (Appendix A) 3. Complete %2+-/ %2CF+ GS1 Data bar RSS-14 Parameters <Transmit RSS-14 Check Digit> Do Not Transmit RSS-14 Check Digit %0UN7 Transmit RSS-14 %0UN5 Application ID Do Not Transmit RSS-14 Application ID %0U88 Transmit RSS-14...
  • Page 38 Wireless Linear CCD Barcode Scanner Transmit RSS Limit Symbology ID <Do Not Transmit RSS Limit Symbology ID> %0V44 %0V40 RSS Expanded Parameters Transmit RSS Expanded Symbology ID <Do Not Transmit RSS Expanded Symbology ID> %0W44 %0W44...
  • Page 39: Chapter 8: Miscellaneous Parameters

    User Manual Chapter 8: Miscellaneous Parameters Language Selection <US English> %0ZV0 UK English %0ZV1 Italiano %0ZV2 Español %0ZV3 Français %0ZV4 Deutsch %0ZV5 Svenska %0ZV6 Suisse %0ZV7 Magyar %0ZV8 Japanese %0ZV9...
  • Page 40: Barcode Id

    Wireless Linear CCD Barcode Scanner Belge/Belgier/ Belgisch Português %0ZV0 Dansk %0ZV0 Nederlands %0ZV0 Türk %0ZV0 Reserved2 %0ZV0 %0ZV0 Barcode ID Default IDs <OFF> %00H1 Default %00H0 %913+ With the Barcode ID function ON, the system adds a leading character to the output barcode string when a code is scanned.
  • Page 41 User Manual User-Defined IDs To set a unique barcode ID, scan the barcode for the symbology you want to change (see below). Then, scan the ASCII code in Appendix B that represents the desired code ID. NOTE: A user-defined code ID will override a default value. The system will not check for conflicts with other assigned codes.
  • Page 42 Wireless Linear CCD Barcode Scanner CODE 93 CODE 11 %91K+ China Postage %91L+ MSI/PLESSEY %91M+ BC412 %91N+ Telepen %91O+ %91T+ CODE 2 of 6 RSS-14 %91P+ %91U+ LCD 25 RSS Expanded %91Q+ RSS Limit %91W+ Reserved 6 %91V+ %91S+ Reserved 5 %91R+...
  • Page 43: Reading Level

    User Manual Reading Level Bar Equals High <Bar Equals Low> %03I2 %0310 Accuracy <One Time> Two Times %0130 Three Times %0131 Four Times %0132 %0133 Buzzer Tone <High> Medium %01J3 %01J2 %01J1 %01J0 Indicator LED ON/OFF (SV700 only) LED ON LED OFF %09O8 %09O0...
  • Page 44: Continuous-Reading-Mode Sensitivity

    Wireless Linear CCD Barcode Scanner Continuous-Reading-Mode Sensitivity Quick Setting <Fast> Slow %0388 %0380 Same-Symbol Timeout In Continuous/Flash reading mode, this function sets a delay for rescanning a barcode that is still in the scan field. Users can define values from 1 – 50 (100 ms to 5 seconds respectively, graded in 100 ms increments (default is 3 [0.3 s]).
  • Page 45 User Manual Output-Character Deletion To Set Up Deletion of Output Characters 1. Scan the barcode of the desired set in the section titled “Select Deletion-Set Number” below. 2. Scan the barcode for the desired symbology in the section titled “Symbologies” below. 3.
  • Page 46 Wireless Linear CCD Barcode Scanner EAN-13/JAN-13 %81Y+ EAN-8/JAN-8 %81Z+ CODE 39 %81E+ CODE 128 %81F+ CODABAR/NW7 %81J+ Interleave 25 %81G+ Industrial 25 %81H+ Matrix 25 %81I+ CODE 93 %81K+ CODE 11 %81L+ China Postage MSI/PLESSEY %81M+ %81N+...
  • Page 47: Setup Insertion

    User Manual CODE 2 of 6 Telepen %81P+ RSS-14 %81T+ LCD 25 %81U+ RSS Expanded %81Q+ RSS Limit %81W+ %81V+ All Codes None %81S+ %814+ Character Position to Be Deleted 1. Decimal Value 2. Complete (Appendix A) %820+ Number of Characters to Be Deleted 1.
  • Page 48 Wireless Linear CCD Barcode Scanner position to be inserted. 4. Scan the “Complete” barcode in the section titled “Character Position to Be Inserted” below. 5. Refer to the ASCII tables in Appendix B or the Function Key tables in Appendix C and scan the barcode that represents the desired characters to be inserted.
  • Page 49 User Manual CODE 39 %51E+ CODE 128 %51F+ CODABAR/NW7 %51J+ Interleave 25 %51G+ Industrial 25 %51H+ Matrix 25 %51I+ CODE 93 %51K+ CODE 11 %51L+ China Postage %51M+ MSI/PLESSEY %51N+ CODE 2 of 6 Telepen %51P+ %51T+...
  • Page 50 Wireless Linear CCD Barcode Scanner RSS-14 LCD 25 %51U+ %51Q+ RSS Expanded RSS Limit %51W+ %51V+ All Codes None %51S+ %514+ Character Position to Be Inserted 1. Decimal Value 2. Complete (Appendix A) %520+ Characters to Be Inserted 1. Decimal Value 2.
  • Page 51: Decimal Value Table

    User Manual Appendix A Decimal Value Table...
  • Page 52: Ascii Table

    Wireless Linear CCD Barcode Scanner Appendix B ASCII Table...
  • Page 53 User Manual "...
  • Page 54 Wireless Linear CCD Barcode Scanner...
  • Page 55 User Manual...
  • Page 56: Function Key Table

    Wireless Linear CCD Barcode Scanner Appendix C Function Key Table Home Down...
  • Page 57: Main Settings

    User Manual Main Settings Use the following codes to configure the scanner. Save Parameters The parameter settings will be saved permanently. %$ + / 0 Recall Stored Parameters Replace the current parameters by the parameters you saved last time. %$ + / 1 Set All Defaults Set all the parameters to the factory default settings.
  • Page 58 ITALIANO: Per informazioni sulla garanzia, accedere a manhattanproducts.com/t/warranty. EN MÉXICO: Póliza de Garantía Manhattan — Datos del importador y responsable ante el consumidor IC Intracom México, S.A.P.I. de C.V. • Av. Interceptor Poniente # 73, Col. Parque Industrial La Joya, Cuautitlán Izcalli, Estado de México, C.P. 54730, México. •...
  • Page 59 1. Todos los productos a que se refiere esta garantía, ampara su cambio físico, sin ningún cargo para el consumidor. 2. El comercializador no tiene talleres de servicio, debido a que los productos que se garantizan no cuentan con reparaciones, ni refacciones, ya que su garantía es de cambio físico.
  • Page 60 All trademarks and trade names are the property of their respective owners. © IC Intracom. All rights reserved. Manhattan is a trademark of IC Intracom, registered in the U.S. and other countries.

Table of Contents