Content Introduction................1 1.1 General ..............1 1.2 EMI certificated ............1 1.3 Legislation and WEEE symbol ........ 1 1.4 Pin Assignment ............2 How to Configure..............3 2.1 Flow Chart ............... 3 2.2 General Process ............. 3 2.3 Start Over ..............4 2.4 Recall ..............
Introduction 1.1 General SG300RFM has been factory configured with a set of default parameters. All factory default settings are shown with <> and bold in the following sections. You may make your own settings by following procedures in this manual. If you want to save the settings permanently, you should scan the Bar Code of “Save Parameters”...
This marking shown on the product or its literature, indicates that it should not be disposed with other households wastes at the end of its working life. To prevent possible harm to the environment or human healthy from uncontrolled waste disposal , please separate this from other types of wastes and recycle it responsibly to promote the sustainable reuse of material resources.
How to Configure 2.1 Flow Chart Start Recall Set All Configuration Parameters Defaults Bar Codes Parameters About Configuration Configuration Save Parameters 2.2 General Process Step1 Power on the scanner and cradle Step2 Scan Start of configuration Step3 Scan the barcodes for the desired features before scan End.
2.3 Start Over Abort configuration Scan Abort configuration when you want to terminate current programming status. 2.4 Recall Replace the current parameters by the parameters saved last time. 2.5 Set All Default Set all the parameters to the factory default settings. 2.6 Version Information Display the decoder version information and...
Operation 3.1 Beeper Option <High> Medium 3.2 Output Characters This function is related to the software of the host. The output results will be affected by the software. None Data are displayed continuously <CR+LF> The cursor moves to the left once data are displayed, and it will move to the next line when the next data is ready to...
Page 9
Enable CR Suffix – The scanner transmits a carriage return after each scan. The cursor moves to the left once data are displayed. Enable LF Suffix – The scanner transmits a line feed after each scan. The cursor moves to the next line once data are displayed.
Number as keypad data Once this function is activated, the output of the scanning comes from the numerical pad’s code. <number as normal data> Enable STX-ETX Before displaying a data, this function will add a STX ASCII code in front of the data, and an ETX ASCII code at the end of the data.
please lock the keyboard before testing the scanner. Enable Upper Case Output characters in upper case. The results will be affected by the keyboard settings. Thus, please lock the keyboard before testing the scanner. Enable CapsLock Detection Disable CapsLock Detection 3.5 Interscan Code Delay Delay the characters output time.
Code Type 4.1 Code Selection If “Enable” is selected for all the barcode types, then the scanner could read all types of barcode. If “Disable” is selected for a certain barcode type, then the scanner could not read the particular barcode. The symbol of “< >”...
4.2 Bar Code ID With this function on, a leading character will be added to the output string while scanning code; user may refer to the following table to know what kind of barcode is being scanned. Enable Bar Code ID Disable Bar Code ID Default Code Type...
4.3 User Define Code ID User define code ID will override default value. It is possible to have more than two symbologies which have same code ID Step1 Scan the Bar Code You wish to define Step2 Go to ASCII Table Appendix B, scan Bar Code(s) that represents the desired code ID UPC-A UPC-E...
4.4 UPC/EAN/JAN Reading Type > Enable UPC-A= EAN 13 add 0 before UPC-A to make it 13 digits. <Disable UPC-A = EAN 13> Enable ISBN-10 =Disable ISBN-13 <Disable ISBN-10> =Enable ISBN-13 If you need to use ISBN-13, Please turn on EAN 13 Check Digit Transmission Function as well.
Enable GTIN format <Disable GTIN format> Supplemental Setup > <No Supplement Required> Enable 2 Digit Supplemental Enable 5 Digit Supplemental Enable 2 & 5 Digit Supplemental Check Digit Transmission > If “Check Digit” is selected, the scanner will transmit the check digit. If “Disable” is selected, the scanner will not transmit the check digit.
Calculate Check Digit and Transmit Calculate Check Digit and Not Transmit Output Start / Stop Character > <start/stop character = “*”> Enable Start/Stop Character <Disable Start/Stop Character> Decode Asterisk > Enable Decode Asterisk The scanner will decode the “*” symbol in code 39. <Disable Decode Asterisk>...
Page 24
same as the barcode’s length. There is no limit in length for the reading output. Fix Length (2 sets Available) Set Begin Decimal Value Appendix A Set Complete Set Begin Decimal Value Appendix A Set Complete Minimum Length Minimum Length Set a minimum length for codes.
4.6 Code 128 Check Digit Transmission > Do Not Calculate Check Digit Calculate Check Digit and Transmit <Calculate Check Digit and Not Transmit> Append FNC2 > “FNC2” is a multi codes-connection function for Code 128. Sometimes a Code 128 is divided into two barcodes for large amount of data.
Page 26
< Variable> The output would be the same as the barcode’s length. There is no limit in length for the reading output. Fix Length (2 sets Available) 1st Set Begin Decimal Value Appendix A Set Complete Set Begin Decimal Value Appendix A Set Complete Minimum Length...
Minimum Length Complete 4.7 Interleave 25 Check Digit Transmission > <Do not Calculate Check Digit> Calculate Check Digit and Transmit Calculate Check Digit and Not Transmit Setup Number of Character > <Set up Digit Number as Even> “Even” means the Interleave 25 code will be output in even numbers.
Page 28
Brazilian Banking Code > Enable Brazilian Banking Code <Disable Brazilian Banking Code> Setup Code Length > Scan the “Set Begin” Bar Code (2 Sets Available) Go to Decimal Value Table in Appendix A, scan Bar Code(s) that represents the code length Scan the “Complete”...
Minimum Length Minimum Length Set a minimum length for codes. If the length of a code is shorter than the minimum length, then the scanner will not output the data. Appendix A Minimum Length Complete 4.8 Industrial 25 Check Digit Transmission >...
Page 30
There is no limit in length for the reading output. Fix Length (2 Sets Available) 1st Set Begin Decimal Value Appendix A Set Complete Set Begin Decimal Value Appendix A Set Complete Minimum Length Minimum Length Set a minimum length for codes.
IATA 25 > Enable IATA 25 <Disable IATA 25> 4.9 Matrix 25 Check Digit Transmission > <Do not Calculate Check Digit> Calculate Check Digit and Transmit Calculate Check Digit and Not Transmit Setup Code Length > Scan the “Set Begin” Bar Code (2 Sets Available) Go to Decimal Value Table in Appendix A, scan Bar Code(s) that represents the code...
1st Set Begin Decimal Value Appendix A Set Complete Set Begin Decimal Value Appendix A Set Complete Minimum Length Minimum Length Set a minimum length for codes. If the length of a code is shorter than minimum length, then scanner will not output the data.
Page 33
<Disable Start/Stop characters> Transmission Type of Start/Stop > <A/B/C/D><Start> <A/B/C/D><Stop> A Start A Stop B Start B Stop C Start C Stop D Start D Stop...
Page 34
Setup Code Length > Scan the “Set Begin” Bar Code (2 Sets Available) Go to Decimal Value Table in Appendix A, scan Bar Code(s) that represents the code length Scan the “Complete” Bar Code Repeat Steps 1-3 to set additional lengths <...
the scanner will not output the data. Decimal Value Appendix A Minimum Length Complete 4.11 Code 93 Check Digit Transmission > < Calculate Check 2 Digit & not Transmit> Do not Calculate Check Digit Setup Code Length > Scan the “Set Begin” Bar Code (2 Sets Available) Go to Decimal Value Table in Appendix A, scan Bar Code(s) that represents the code...
Set Complete Set Begin Decimal Value Appendix A Set Complete Minimum Length Minimum Length Set a minimum length for codes. If the length of a code is shorter than the minimum length, then the scanner will not output the data. Decimal Value Appendix A Minimum Length...
Page 37
Calculate Check 2 Digit and Transmit Calculate Check 2 Digit and Not Transmit Setup Code Length > Scan the “Set Begin” Bar Code (2 Sets Available) Go to Decimal Value Table in Appendix A, scan Bar Code(s) that represents the code length Scan the “Complete”...
Minimum Length Minimum Length Set a minimum length for codes. If the length of a code is shorter than the minimum length, then the scanner will not output the data. Decimal Value Appendix A Minimum Length Complete 4.13 MSI/PLESSEY Code Check Digit Transmission >...
Page 39
< Variable> The output would be the same as the barcode’s length. There is no limit in length for the reading output. Fix Length (2 Sets Available) 1st Set Begin Decimal Value Appendix A Set Complete Set Begin Decimal Value Appendix A Set Complete Minimum Length...
4.14 Code 2 of 6 Check Digit Transmission > Do not Calculate Check Digit <Calculate Check Digit and Transmit> Calculate Check Digit and Not Transmit Setup Code Length > 1. Scan the “Set Begin” Bar Code (2 Sets Available) 2. Go to Decimal Value Table in Appendix A, scan Bar Code(s) that represents the code length 3.
Set Complete Minimum Length Minimum Length Set a minimum length for codes. If the length of a code is shorter than the minimum length, then the scanner will not output the data. Decimal Value Appendix A Minimum Length Complete 4.15 Telepen Type of Code >...
Page 42
Setup Code Length > Scan the “Set Begin” Bar Code (2 Sets Available) Go to Decimal Value Table in Appendix A, scan Bar Code(s) that represents the code length Scan the “Complete” Bar Code Repeat Steps 1-3 to set additional lengths <...
the scanner will not output the data. Decimal Value Appendix A Minimum Length Complete Minimum Length Complete 4.16 LCD 25 Check Digit Transmission > Do not Calculate Check Digit Calculate Check Digit and Transmit <Calculate Check Digit and Not Transmit> Setup Code Length >...
Fix Length (2 Sets Available) 1st Set Begin Decimal Value Appendix A Set Complete Set Begin Decimal Value Appendix A Set Complete Minimum Length Minimum Length Set a minimum length for codes. If the length of a code is shorter than the minimum length, then the scanner will not output the data.
PREFIX/SUFFIX 5.1 Standard Suffixes None Data are displayed continuously <CR+LF> The cursor moves to the left once data are displayed, and it will move to the next line when the next data is ready to be displayed. (This function is related to the software of the host, and the results will be affected by the software) Enable CR Suffix –...
Enable Space Once data are displayed, the cursor will skip a space to get ready for the next data. Enable Tab(HT) Once data are displayed, the cursor will skip a tab to get ready for the next data. Enable STX-ETX Before displaying a data, this function will add a STX ASCII code in front of the data, and...
Page 49
Scan “End” Scan “Save” Repeat Steps 1-6 to set additional set Example Insert $ as Prefixes for Code UPC-A > Start Set #1 Scan the bar code for the desired Set Code UPC-A Scan the bar code of the desire bar code type 1st digit Scan Bar Code(s) that represents the position of digit...
Scan “Save” bar code Insertion Set Number > Set #1 Set #2 Set #3 Set #4 Set #5 Set #6 Code Type to be inserted > UPC-A UPC-E EAN-13/JAN-13 EAN-8/JAN-8 CODE 39...
5.3 Deletion Data You can delete character for up to 6 different barcode types. Steps Scan the bar code for the desired set. Scan the desire bar code type Scan Bar Code(s) that represents the digit number of start position to be deleted Scan the “Compete”...
Page 55
Complete Scan the numbers of characters need to be deleted Complete Save Delectation Set Number > Set #1 Set #2 Set #3 Set #4 Set #5 Set #6 Code Type to be deleted >...