Heg series 14-inch camera enclosure with optional sunshield, heater and blower kits (16 pages)
Summary of Contents for Ultrak KD6 Z Series
Page 1
KD6 Z-SERIES DOME OPERATION AND PROGRAMMING Manual Number 518854-1960 Ultrak ® 4465 Coonpath Road Carroll, OH 43112 (800) 443-6680•(740) 756-9222•FAX (740) 756-4237 Issue 1, Revision D – April 25 , 2001...
Page 2
PERMISSION FROM ULTRAK , INCORPORATED. THE INFORMATION IN THIS PUBLICATION IS BELIEVED TO BE ACCURATE IN ALL RESPECTS. HOWEVER, ULTRAK, INCORPORATED CANNOT ASSUME RESPONSIBILITY FOR ANY CONSEQUENCES RESULTING FROM THE USE THEREOF. THE INFORMATION CONTAINED HEREIN IS SUBJECT TO CHANGE WITHOUT NOTICE. REVISIONS OR NEW EDITIONS TO...
Page 3
WARNING THIS IS A CLASS A PRODUCT. IN A DOMESTIC ENVIRONMENT, THIS PRODUCT MAY CAUSE RADIO INTERFERENCE IN WHICH CASE THE USER MAY BE REQUIRED TO TAKE ADEQUATE MEASURES. WARNING TO REDUCE A RISK OF FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE THIS PRODUCT TO RAIN OR MOISTURE UNLESS ENCLOSED IN A WATERPROOF HOUSING.
Page 4
IEC-1000-4-3, RF Fields, IEC-1000-4-4, Fast Transients/Burst. EN60065 - Safety Requirements for Mains Operated Electronic and Related Apparatus for Household and Similar General Use. Ultrak, Inc. hereby declares that the models specified above conform to the directive and standard as specified. Donald L. Stephenson...
Page 5
IMPORTANT SAFEGUARDS Read Instructions - All the safety and operating instructions should be read before the unit is operated. Retain Instructions - The safety and operating instructions should be retained for future reference. Heed Warnings - All warnings on the unit and in the operating instructions should be adhered to. Follow Instructions - All operating and use instructions should be followed.
Page 6
When the unit exhibits a distinct change in performance - this indicates a need for service. Replacement Parts - When replacement parts are required, be sure the service technician has used replacement parts specified by the manufacturer or have the same characteristics as the original part.
Page 7
SAFETY PRECAUTIONS CAUTION RISK OF ELECTRIC SHOCK, DO NOT OPEN CAUTION: TO REDUCE THE RISK OF ELECTRICAL SHOCK, DO NOT OPEN COVERS. NO USER SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL. This label may appear on the bottom of the unit due to space limitations. The lightning flash with an arrowhead symbol, within an equilateral triangle, is intended to alert the user to the presence of uninsulated “dangerous voltage”...
Page 8
HANDLING ELECTROSTATIC-SENSITIVE DEVICES ATTENTION OBSERVE PRECAUTIONS FOR HANDLING ELECTROSTATIC SENSITIVE DEVICES WARNING ELECTROSTATIC SENSITIVE DEVICE. USE PROPER CMOS/MOSFET HANDLING PRECAUTIONS TO AVOID ELECTROSTATIC DISCHARGE. NOTE: Grounded wrist straps must be worn and proper ESD safety precautions observed when handling the electrostatic-sensitive printed circuit boards.
KD6 Z-SERIES DOME OPERATION AND PROGRAMMING DESCRIPTION A KD6 Z-Series Dome consists of: A pan and tilt assembly, often referred to as a "scan". A color camera (NTSC or PAL) with an auto-focus and auto-iris lens. Top Dome Bottom Dome The KD6 Z-Series Dome can be mounted in a dropped ceiling, hard ceiling, indoor pendant dome, or outdoor weather dome.
OPERATION The KD6 Z-Series Dome can be controlled and programmed using any Diamond JPD Series Joystick Controllers. The controllers must have the following firmware revision level to support the KD6 Z-Series Dome. Controller Firmware Part Number Model and Revision L JPD101 518007-3980, Revision F or later JPD100...
Page 13
JPD Series Controller (secondary control camera, if selected; if not, primary control camera) Note: refer to the JPD Series Controller user’s manual for operation of primary control and secondary control cameras. Enter the PreShot number (1-64). Press PSHOT. Example: Send primary control camera (no secondary camera selected) to PreShot 5. Press 5 on the numeric keypad.
PROGRAMMING A JPD Series Controller is used to program and store PreShots and VectorScans in the scan. The following criteria has to be met to program (or edit existing programming in) a scan. 1. The scan being programmed must be the primary control camera on the controller. 2.
Perform the following procedure to program a PreShot in the KD6 Z-Series Dome using a JPD100, JPD100P, or JPD200P Controller. JPD100, JPD100P, or JPD200P Controller a. Adjust the pan, tilt, zoom, and focus of the KD6 Z-Series Dome using the joysticks on the controller until the desired scene is displayed on the monitor.
Press Enter. Continue entering PreShot numbers and dwell times (up to 16). • • Press Clear when done programming. 4.2.1 Editing VectorScans Edit VectorScans by reprogramming the VectorScan as described in paragraph 4.2. Note: All previous programming for the VectorScan is lost. Table 1.
Page 17
CAMERA LOG Camera Camera Serial # System Address Serial # System Address (8-digits) (1-250) (8-digits) (1-250) _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _...
Page 18
PRESHOT LOG Camera Serial # _ _ _ _ _ _ _ _ (8 digits) System Address _ _ _ (1-250) PreShot # View...
Page 19
VECTORSCAN LOG Camera Camera Serial # _ _ _ _ _ _ _ _ (8 digits) Serial # _ _ _ _ _ _ _ _ (8 digits) System Address _ _ _ (1-250) System Address _ _ _ (1-250) VectorScan # __ (1-3) VectorScan # __ (1-3) Dwell Time...
Need help?
Do you have a question about the KD6 Z Series and is the answer not in the manual?