Appendix 5 Internal data

Table 8-7 is the internal data that the My function-S can handle.
This data is not rewritable. It can be used only as input data for comparison and computation.
Table 8-7 Data that My function-S can handle
Input setting















Monitor

display output

value













Communication
No.
FE00
Operation frequency
FE02
Frequency setting value
FE03
Output current
FE04
Input voltage (DC detection)
FE05
Output voltage
FE14
Comulative operation time
FE15
Frequency setting value (after compensation)
FE18
Torque
FE22
PID feedback value
FE23
Motor cumulative load factor
FE24
Inverter cumulative load factor
FE25
Braking resistance cumlative load factor
FE26
Motor load factor
FE27
Inverter load factor
FE29
Input power
FE30
Output power
FE35
VIA input value
FE36
VIB input value
FE37
VIC input value
FE40
FM output value
FE70
Inverter rated current
FE76
Integral input power
FE77
Integral output power
FE80
Cumulative power ON time
FD32
Number of starting
FD33
Number of forward starting
FD34
Number of reverse starting
FD40
Pulse train output value
FD41
Cumulative fan operation time
Inverter rated current
FD70
(Carrier frequency corrected)
- 35 -
Function
E6581865
Unit
(Communication)
0.01Hz
0.01Hz
0.01%
0.01%
0.01%
1=1hour
0.01Hz
0.01%
0.01Hz
0.01%
0.01%
1%
1%
1%
0.01kW
0.01kW
0.01%
0.01%
0.01%
0.01%
0.1A
It depends on
f749
It depends on
f749
1=10hours
1=1000times
1=1000times
1=1000times
pps
1=10hours
0.1A