<Example 4: Output signal by logical product of 2 functions>
Output the signal on the condition of detecting both a low-speed signal and a small
current signal from Terminal OUT.
See Fig 5-7 for block diagram.
Compute by logical product (AND) of a low-speed signal and a small current signal.
Transfer the result to the My function-S output1, and output signal from Terminal OUT.
Paramerter setting
Title
Prior
a977  (Default)
–
setting
f131 
Step 1
a900 
a901 
Step 2
a902 
Unit 1
a903  (Default)
Step 3
a904  (Default)
Step 4
a905 
–
a977 
Computations by
My function-S
Low-speed
signal
Inverter function
Small-current
signal
Fig. 5-7 Block diagram for Example 4
Parameter setting
Set to "Disabled" of the My function-S.
Assign the My function-S output 1 to the Terminal OUT.
Read the low speed signal (LD LOW)
AND command
The logical product of low speed signal and small
current signal.
NOP command (no operation)
Transfer the logical product to the My function-S
output 1.
Set to "My function-S always ON".
VF-S15
My function-S
output 1
Description
- 16 -
E6581865
OUT