Enable or disable state of My function-S
You can set enable or disable state of the My function-S
When you set the My function-S parameters, be sure to set a = (disabled) to
prevent the system from starting accidentally.
After setting the My function-S parameters, change to (My function-S + permission
signal) or (My function-S always ON) to make My function-S ready to be enabled. (If you set
=, My function-S is enabled when a permission signal is issued.)
Note: It takes a maximum of 0.5 second for a change of the My function-S parameters to be
reflected internally. Keep standby state at least 0.5 second after setting the parameters.
Title
(Disabled):
My function-S is disabled.
(My function-S + permission signal):
My function-S is in standby state.
When you put input signal into the input terminal assigned functions or (My
function-S trigger signal), the My function-S is enabled.
(My function-S always ON):
My function-S is enabled when the inverter is turned on.
Note: You cannot change the parameter during inverter operation.
● In case that the My function-S is disabled
The My function-S settings are disabled.
If the input terminals are turned on, the inverter operates by the input terminal function.
● In case that the My function-S is in a standby state
All signals except the followings are recognized as OFF signals inside of the inverter.
1. My function-S trigger signal
2. Emergency stop and reset command
Note: Don't use the input terminals assigned the above functions in the My function-S. Or the
My function-S permission, the emergency stop function, etc might not activate normally.
● In case that My function-S is enabled
If the input terminals are turned on, the inverter operates by the My function-S.
Function
My function-S selection
Adjustment range
: Disabled
: My function-S + permission signal
: My function-S always ON
- 11 -
E6581865
Default setting