INSTALLATION
Installation
9.
Installation
9.1

Appliance installation

f Use the template to mark the drill holes (SN 10 SLi |
f
SN 10 SL GB | SN 15 SLi | SN 15 SL 3.3 kW supplied separately
or SN 5 SLi | SN 5 SL GB inside these instructions).
f Drill the holes and insert suitable rawl plugs.
f
f Secure the wall mounting bracket using suitable screws.
f
f Hang the appliance on the wall mounting bracket.
f
Note
Surplus cable can be stored in the cable compartment.
9.2

Water connection

Material losses
!
Carry out all water connection and installation work in
accordance with regulations.
Material losses
!
Counterhold with a suitable spanner when tightening
fittings.
Material losses
!
The appliance may develop a leak and cease functioning.
f Never subject the appliance to water pressure.
f
f Never interchange the water connections.
f
f Set the flow rate (see tap instructions). Observe the
f
maximum permissible flow rate with a fully opened
tap (see chapter "Installation / Specification / Data
table").
www.stiebel-eltron.com 
Note
The levers for the twin-lever mixer tap for oversink in-
stallation are delivered DIN 44897-compliant:
- Cold water on the left (blue)
- Hot water on the right (red)
f Secure the water connections from the tap to the appliance.
f
9.3

Power supply

WARNING Electrocution
Carry out all electrical connection and installation work
in accordance with relevant regulations.
WARNING Electrocution
When permanently connected to the power supply using
a dedicated junction box, the appliance must be able to
be isolated from the mains power supply by an isolator
that disconnects all poles with at least 3 mm contact
separation.
WARNING Electrocution
Ensure that the appliance is earthed.
Material losses
!
The voltage specified on the type plate must match the
mains voltage.
f Observe the type plate.
f
The following electrical connections are permissible:
SN 5 
SLi
SL GB
Connection to a freely
X
accessible standard
socket with matching
plug
Permanent connection
X
to an appliance junction
box with earth conductor
Fixed power cable with
-
the permanent connec-
tion set
The permanent connection set maintains the IP 24 D protection
rating when converting the appliance.
SN 5 
SN 10 
SN 10 
SN 15 
SN 15 SL 
SLi
SL GB
SLi
3.3 kW
X
X
X
X
X
X
X
X
-
-
-
X
SN 5  | SN 10  | SN 15  |
X
X
X
19