P30 Group Control's Sub Unit Error (* Warning Displayed Only On System Controller - Panasonic 2WAY Multi Technical & Service Manual

Troubleshooting. gas heat pump, air conditioner.
Hide thumbs Also See for 2WAY Multi:
Table of Contents

Advertisement

P30 Group Control's Sub Unit Error (* warning displayed only on system controller)

Error detection method
When an error occurs on a group control sub unit (for all abnormalities), the system controller displays P30.
Troubleshooting
1
1-1
Confi rm error details using one of the following methods.
Check warning display on wired remote controller.
Check warning history in system controller servicing check mode.
1-2
Troubleshoot the warning found in 1-1.
● For board and Electrical Wiring Diagram, see Chapter 6.
• Outdoor main board: page VI-2
• Outdoor power board: page VI-3
• Converter board: VI-4
• Indoor control board for DC motor models: page VI-5
• Outdoor Unit Electrical Wiring Diagram: page VI-6
● 1-1
System controller service check mode (warning history)
Indoor unit/outdoor unit warning history monitoring mode (also clears warning history)
Press the Inspect icon and Set button continuously for 4 seconds or more.
Service Check lights, and the item code "   " lights.
When the group number is selected (when [1] is fl ashing), when any warning history exists, the newest
warning history is displayed alternately with the unit number.
* Temperature settings are not available.
To check older warning history, press the temperature setting ▲ button or ▼ button, and select the
item code (01~04).
To check warnings for other groups, press the Switch Group
group number.
To clear the warnings, press the cancel button.
(This deletes the entire warning history for the currently selected group.)
To end the servicing check, press the Inspect button.
Unit No.
Displayed alternately
System
Indoor
Unit No. Display
IV–104
Inspection
Alarm Display
button or
button, and select the