6.12
Connecting the 24 V DC Output Power Cable
You can connect one or two 24 V DC output power cables to the smart array controller that
supports 24 V DC input and output. DC output power cables are connected in the same manner.
This section describes how to connect one route of DC output power cable.
Port on the JX02
No.
Terminal Block
1, 2
24VOUT+
3, 4
24VOUT–
1. Prepare a cable.
2. Connect the 24 V DC
output power cable to
the JX02 terminal block.
Do not connect the cable
reversely.
3. Bind the cable.
6.13
Connecting the 24 V DC Input Power Cable
You can connect one 24 V DC input power cable to the smart array controller that supports 24 V
DC input and output.
Port on the JX02
No.
Terminal Block
5
24VIN+
6
24VIN–
1. Prepare a cable.
2. Connect the 24 V DC
input power cable to the
JX02 terminal block.
Do not connect the cable
reversely.
3. Bind the cable.
Definition
Positive terminal of the 24
V DC output power cable
Negative terminal of the 24
V DC output power cable
Definition
Positive terminal of the 24
V DC input power cable
Negative terminal of the 24
V DC input power cable
24