Triggering with an Externa! Signal
Trigger one- or two-channel displays with an externally applied signal using
the following procedure:
Step 1: Apply the external signal to the EXT INPUT connector using a
coaxial cable.
Step 2: Set the SOURCE to EXT
Step 3: Select the EXT COUPL mode: AC, DC, or DC ™ 10.
Step 4: Adjust the TRIGGER LEVEL for a stable display.

Triggering on TV Signals

You can trigger on either TV line or TV field signals.
Triggering on a TV Line Signal
H
Step 1: Push in the P-P AUTO/TV LINE trigger mode button.
Step 2: Apply the TV signal to a channel input and display the channel.
Step 3: Set the VOLTS/DIV switch to display 0.3 or more of composite
video signal.
P I Step 4: Set the SEC/DIV switch to 10 ps.
P I Step 5: Set the TRIGGER SLOPE switch either out (for positive-going
TV Signal sync pulses) or in (for negative-going TV signal sync pulses).
Step 6: Adjust the TRIGGER LEVEL stabilize the display (Figure 3-27).
= 0 . f i
0 0
a u i
' — 1
J M
If
in * * t
i m l
i f
0 . 5 U

Figure 3-27: Multi-burst Signal Triggered in TV Line

Triggering on TV Field
S tepl: Set the TRIGGER Mode to TV FIELD. (Press the P-P AUTO and