2.10.2
Terminal block on MS20/MS30-...E...
Products with voltage range E (product code position 15
one 6-pin terminal block.
1
+24 V (P1)
2
3
0 V
Relay
0 V
4
5
+24 V (P2)
6
7
Figure 17: Pin assignment of the 6-pin terminal block
1 - Pin 1 = +24V (P1)
2 - Pin 2 = Relay
3 - Pin 3 = 0 V
4 - Pin 4 = 0 V
5 - Pin 5 = Relay
6 - Pin 6 = +24V (P2)
7 - Terminal block for power and signal contact
8 - MICE MS20/30-...E... switch basic module with 18 V DC ... 60 V DC
voltage range /6-pin
2.10.3

Startup procedure

 Mount the terminal blocks for the voltage supply and signal contact on the
bottom of the device using the snap locks. Make sure that the snap lock
snaps into place.
By connecting the voltage supply via the terminal blocks, you start the
operation of the device.
Installation MS20/MS30
Release 11 07/2013
7