5 SETTINGS

The control connections (analogical input / output, digital
inputs / outputs and RS485 interface) must be performed
as shown in
figure
Connector
1
DO1-RL-NO
3
DO1-RL-C
5
DO1-RL-NC
7
DO3-RL-NO
9
DO3-RL-C
11
DO3-RL-NC
13
15
17
19
21
23
2
4
6
8
10
DO2-TR
12
RS485 - A(-)
14
RS485 - B(+)
16
18
20
RS485 – A2(-)
22
RS485 - B2(+)
24
Figure 1: Signals of control connector
RS485 Communication Plug-in Module
1.
Digital output 1
(NO contact of relay 1)
Digital output 1
(common point of relay 1)
Digital output 1
(NC contact of relay 1)
Digital output 3
(NO contact of relay 2)
Digital output 3
(common point of relay 2)
Digital output 3
(NC contact of relay 2)
NC
Not connected
+24 V
+24 Vdc Power suply
DI1
Digital input 1
DI2
Digital input 2
DI3
Digital input 3
DI4
Digital input 4
AO1
Analogical output 1
GND
Reference 0 V
AI1
Analogical input 1
Reference +10 Vdc for
+10 V
potentiometer
Digital output 2 (transistor)
RS485 (Terminal A(-))
RS485 (Terminal B(+))
GND
Reference 0 V
AI2
Analogical input 2
RS485 (Terminal A2(-))
RS485 (Terminal B2(+))
GND
Reference 0 V
Description
CFW500 | 7