Time
Parameter
Meaning
Bottom synchro-
Bottom PTP synchronization thresh-
nization thresh-
old value, specified in nanoseconds.
old [ns]
If the result of (reference time - local
time) is lower than the value of the
bottom PTP synchronization thresh-
old, then the local clock is deemed
as synchronous with the reference
clock.
Top synchroni-
Top PTP synchronization threshold
zation threshold
value, specified in nanoseconds. If
[ns]
the result of (reference time - local
time) is greater than the value of the
top PTP synchronization threshold,
then the local clock is deemed as
not being synchronous with the
reference clock.
Table 13: Configuration IEEE 1588/PTP
Parameter
Meaning
Is synchronized Local clock synchronized with
reference clock; compare Bottom
synchronization threshold
and Top synchronization
threshold.
Max Offset
Total deviation of the local clock
absolute [ns]
from the reference clock in nano-
seconds since the local clock was
last reset. The local clock is reset
with "Reinitialize" in this dialog or by
resetting the device.
Table 14: IEEE 1588/PTPStatus

3.2.2 PTP Version 1 (MS20/MS30, Power MICE)

You select the PTP version you want to use in the Time:PTP:Global
dialog.
RM Web L2E
Release 5.0 04/09
3.2 PTP (IEEE 1588)
Value range
0-999999999
31-1000000000
Value range
true
false
Default setting
30
5000
Default setting